BS EN 61347-2-10:2001+A1:2009 Lamp controlgear Particular requirements for electronic invertors and convertors for high-frequency operation of cold tubular discharge lamps (neon tubes)

BS EN 61347-2-10:2001+A1:2009

Lamp controlgear Particular requirements for electronic invertors and convertors for high-frequency operation of cold tubular discharge lamps (neon tubes)

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
6240 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
624.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1872.00 Kč
Anglicky Tisk
Skladem
6240 Kč
Označení normy:BS EN 61347-2-10:2001+A1:2009
Počet stran:26
Vydáno:2011-06-30
ISBN:978 0 580 73693 3
Status:Standard
Popis

BS EN 61347-2-10:2001+A1:2009


This standard BS EN 61347-2-10:2001+A1:2009 Lamp controlgear is classified in these ICS categories:
  • 29.140.99 Other standards related to lamps

This part of IEC 61347 specifies particular requirements for electronic invertors and convertors for high-frequency operation of tubular cold-cathode discharge lamps used in signs and luminous discharge tube installations and operating with an output voltage exceeding 1 000 V but not exceeding 10 000 V for direct connection to supply voltages not exceeding 1 000 V at 50 Hz or 60 Hz or 1 000 V d.c.

NOTE 1 In Japan, the output voltage of 15 000 V is acceptable.

The requirements for two types of invertors and convertors, types A and B, are specified as follows:

  • Type A unit: an invertor or convertor operating within the frequency range 20 kHz to 50 kHz, and having an output voltage (between terminals) not exceeding 5 000 V peak, a maximum output current limited to 35 mA (r.m.s.) and 50 mA (peak value). The supply voltage does not exceed 250 V at 50 Hz or 60 Hz or 250 V d.c.

NOTE 2 The output current of a type A unit may be considered as not presenting an electric shock hazard due to the limits on the current and frequency range.

NOTE 3 In Japan, the output voltage of 15 000 V is acceptable.

  • Type B unit: an invertor or convertor having a no-load output voltage not exceeding 5 000 V to earth or 10 000 V between terminals, operating within the frequency range 10 kHz to 100 kHz with a maximum output current limited to 200 mA (r.m.s.) and 400 mA (peak value).

NOTE 4 Type B units require additional protection in the output circuit.

NOTE 5 In Japan, a type B unit exceeding 50 mA and/or the secondary grounded is not acceptable.

In order to check the safety of invertors or convertors, it is necessary to check their performance. However, since no standardization of the characteristics of neon tubes exists, reference loads are specified in this standard to ensure reproducible test results.

The rated maximum operating temperature of the winding, tw, is not applicable to this standard.