Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>BS EN 61788-2:2007 Superconductivity Critical current measurement. D.C. critical current of Nb<sub>3</sub>Sn composite superconductors
Sponsored link
sklademVydáno: 2007-02-28
BS EN 61788-2:2007 Superconductivity Critical current measurement. D.C. critical current of Nb<sub>3</sub>Sn composite superconductors

BS EN 61788-2:2007

Superconductivity Critical current measurement. D.C. critical current of Nb<sub>3</sub>Sn composite superconductors

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
7998 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
799.80 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2399.40 Kč
Anglicky Tisk
Skladem
7998 Kč
Označení normy:BS EN 61788-2:2007
Počet stran:40
Vydáno:2007-02-28
ISBN:978 0 580 50219 4
Status:Standard
Popis

BS EN 61788-2:2007


This standard BS EN 61788-2:2007 Superconductivity is classified in these ICS categories:
  • 17.220.20 Measurement of electrical and magnetic quantities
  • 17.220.01 Electricity. Magnetism. General aspects
  • 29.050 Superconductivity and conducting materials
This part of IEC 61788 covers a test method for the determination of the d.c. critical current of Nb3Sn composite superconductors which are fabricated by either the bronze process or the internal tin diffusion process and have a copper/non-copper ratio larger than 0,2. This method is intended for use with superconductors which have critical currents of less than 1 000 A and n-values larger than 12 under standard test conditions and at magnetic fields of less than or equal to 0,7 times the upper critical magnetic field. The test specimen is immersed in a liquid helium bath at a known temperature during testing. The Nb3Sn composite test conductor has a monolithic structure with a total round-cross-sectional area that is less than 2 mm2. The specimen geometry used in this test method is an inductively coiled specimen. Deviations from this test method which are allowed for routine tests and other specific restrictions are given in this standard. Nb3Sn conductors with critical currents above 1 000 A or total cross-sectional areas greater than 2 mm2 can be measured with the present method with an anticipated reduction in precision and a more significant self-field effect (see Annex C). Other, more specialized, specimen test geometries may be more appropriate for larger conductor testing which have been omitted from this present standard for simplicity and to retain precision. The test method given in this standard should in principle apply to Nb3Sn composite wires fabricated by any other process. This method is also expected to apply to other superconducting composite wires after some appropriate modifications.