Cena s DPH / bez DPH
Hlavní stránka>BS EN 674:2011 Glass in building. Determination of thermal transmittance (U value). Guarded hot plate method
Sponsored link
sklademVydáno: 2011-07-31
BS EN 674:2011 Glass in building. Determination of thermal transmittance (U value). Guarded hot plate method

BS EN 674:2011

Glass in building. Determination of thermal transmittance (U value). Guarded hot plate method

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
4650 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
465.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1395.00 Kč
Anglicky Tisk
Skladem
4650 Kč
Označení normy:BS EN 674:2011
Počet stran:16
Vydáno:2011-07-31
ISBN:978 0 580 71595 2
Status:Standard
Popis

BS EN 674:2011


This standard BS EN 674:2011 Glass in building. Determination of thermal transmittance (U value). Guarded hot plate method is classified in these ICS categories:
  • 81.040.20 Glass in building

This European Standard specifies a measurement method to determine the thermal transmittance of glazing with flat and parallel surfaces. Structured surfaces, e.g. patterned glass, can be considered to be flat.

This European Standard applies to multiple glazing with outer panes which are not transparent to far infrared radiation, which is the case for soda lime silicate glass products, borosilicate glass and glass ceramics. Internal elements may be far infrared transparent.

The procedure specified in this European Standard determines the U value1) (thermal transmittance) in the central area of glazing. The edge effects, due to the thermal bridge through the spacer of an insulating glass unit or through the window frame are not included. Furthermore energy transfer due to solar radiation is not taken into account.

The procedure specified in this European Standard should generally only be considered when the calculation method detailed in EN 673 is inappropriate or unsuitable.

The document for the calculation of the overall U value of windows, doors and shutters (see [3]) gives normative reference to the U value evaluated for the glazing components according to this standard.

A vertical position of the glazing is specified.

U values evaluated according to the present standard are used for product comparison as well as for other purposes, in particular for predicting:

  • heat loss through glazing;

  • conduction heat gains in summer;

  • condensation on glazing surfaces;

  • the effects of the absorbed solar radiation in determining the solar factor (see [1]).

Reference should be made to [4], [5], or other European Standards dealing with heat loss calculations for the application of glazing U values determined by this standard.

The determination of the thermal transmittance is performed for conditions which correspond to the average situation for glazing in practice.