Cena s DPH / bez DPH
Hlavní stránka>BS EN IEC 60794-1-212:2024 Optical fibre cables Generic specification. Basic optical cable test procedures. Environmental test methods. Temperature cycling with cable elements fixed at both ends, Method F12
Sponsored link
sklademVydáno: 2024-05-29
BS EN IEC 60794-1-212:2024 Optical fibre cables Generic specification. Basic optical cable test procedures. Environmental test methods. Temperature cycling with cable elements fixed at both ends, Method F12

BS EN IEC 60794-1-212:2024

Optical fibre cables Generic specification. Basic optical cable test procedures. Environmental test methods. Temperature cycling with cable elements fixed at both ends, Method F12

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
7564 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
756.40 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2269.20 Kč
Anglicky Tisk
Skladem
7564 Kč
Označení normy:BS EN IEC 60794-1-212:2024
Počet stran:16
Vydáno:2024-05-29
ISBN:978 0 539 20269 4
Status:Standard
Popis

BS EN IEC 60794-1-212:2024


This standard BS EN IEC 60794-1-212:2024 Optical fibre cables is classified in these ICS categories:
  • 33.180.10 Fibres and cables
IEC 60794-1-212:2024 defines the test procedure to examine the attenuation behaviour (change in attenuation) when an optical fibre cable with cable elements fixed at both ends is subjected to temperature cycling. This test assesses the attenuation behaviour of a cable under a no-end movement condition intended for termination with, for example, interconnecting devices or passive components. This document partially cancels and replaces IEC 60794-1-22:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 60794-1-22:2017: a) the description of the test method has been changed to “with cable elements fixed at both ends”; b) subclauses have been added to the procedure clause; c) the preparation of cable sample and test set-up has been arranged in a logical way; d) Figure 1 has been added for illustration of the preparation of cable sample, DUT and test set-up; e) the temperature chamber temperature tolerance has been changed to ± 3 °C as done in IEC 60794‑1‑22, method F1; f) all required steps have been added to the subclause for temperature cycling as well as the table for the minimum soak time and the figure for the cycle procedure, and removed the reference to IEC 60794-1-22, method F1; g) the maximum change in attenuation has been added to the details to be specified; h) a new subclause 4.5 has been added for details to be reported.