Cena s DPH / bez DPH
Sponsored link
sklademVydáno: 2023-06-07
BS EN IEC 61010-031:2023
Safety requirements for electrical equipment for measurement, control, and laboratory use Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
10048 Kč
Anglicky Tisk
Skladem
10048 Kč
Označení normy: | BS EN IEC 61010-031:2023 |
Počet stran: | 108 |
Vydáno: | 2023-06-07 |
ISBN: | 978 0 539 18798 4 |
Status: | Standard |
Popis
BS EN IEC 61010-031:2023
This standard BS EN IEC 61010-031:2023 Safety requirements for electrical equipment for measurement, control, and laboratory use is classified in these ICS categories:
- 19.080 Electrical and electronic testing
- the scope has been made succinct. General information from the scope of Edition 2 has been moved to a new Clause 4. Consequently, Clause 4 to Clause 8 of Edition 2 have been renumbered. Clause 9 of Edition 2 has been deleted;
- in Clause 2, normative references have been dated and new normative references have been added;
- in 3.1.4, the definition of probe tip has been modified;
- in 4.1, there is no longer any differentiation between high voltage and low voltage probe assemblies. Type C probe assemblies have been merged with Type B probe assemblies;
- in 4.1 d) "Kelvin" probes have been added to the list of probe assemblies as a new Type E and a new Figure 5;
- in 4.1 e), probes for voltage measurement without electrical connection to conductors have been added to the list of probe assemblies as a new Type F and a new Figure 6;
- in 4.2.1, spread of fire is no longer considered as a hazard;
- Subclause 4.4.2.5 from Edition 2 has been deleted;
- Subclause 4.4.4.3 from Edition 2 has been deleted;
- in 5.4.4.1 consideration has been given to spacings and impedance;
- in 6.1.1, removable parts of probe tips which bear markings are allowed;
- in 6.1.5, the voltage to be marked for measurement categories is the AC line-to-neutral or DC voltage;
- in 7.4.2, requirements for unmated connectors have been modified as follows:
- Table 2 has been modified and expanded,
- a calculation method for clearances of connectors above 20 kV has been defined,
- creepage distances have been aligned with clearances;
- in 7.4.3.1 and 7.4.3.5, requirements for IP2X probe tips with retractable sleeve have been added;
- in 7.4.3.2, Probe tips are now applicable to non-contact probe assemblies;
- in 7.5.2.3.2, the values of Table 5 have been modified;