Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>BS EN IEC 61828:2021 Ultrasonics. Transducers. Definitions and measurement methods regarding focusing for the transmitted fields
Sponsored link
sklademVydáno: 2021-02-10
BS EN IEC 61828:2021 Ultrasonics. Transducers. Definitions and measurement methods regarding focusing for the transmitted fields

BS EN IEC 61828:2021

Ultrasonics. Transducers. Definitions and measurement methods regarding focusing for the transmitted fields

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
10230 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
1023.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
3069.00 Kč
Anglicky Tisk
Skladem
10230 Kč
Označení normy:BS EN IEC 61828:2021
Počet stran:118
Vydáno:2021-02-10
ISBN:978 0 580 90717 3
Status:Standard
Popis

BS EN IEC 61828:2021


This standard BS EN IEC 61828:2021 Ultrasonics. Transducers. Definitions and measurement methods regarding focusing for the transmitted fields is classified in these ICS categories:
  • 17.140.50 Electroacoustics

This document

  • provides definitions for the transmitted field characteristics of focusing and nonfocusing transducers for applications in medical ultrasound;

  • relates these definitions to theoretical descriptions, design, and measurement of the transmitted fields of focusing transducers;

  • gives measurement methods for obtaining defined field characteristics of focusing and nonfocusing transducers;

  • specifies beam axis alignment methods appropriate for focusing and nonfocusing transducers.

This document relates to focusing ultrasonic transducers operating in the frequency range appropriate to medical ultrasound (0,5 MHz to 40 MHz) for both therapeutic and diagnostic applications. It shows how the characteristics of the transmitted field of transducers can be described from the point of view of design, as well as measured by someone with no prior knowledge of the construction details of a particular device. The transmitted ultrasound field for a specified excitation is measured by a hydrophone in either a standard test medium (for example, water) or in a given medium. This document applies only to media where the field behaviour is essentially like that in a fluid (i.e. where the influence of shear waves and elastic anisotropy is small), including soft tissues and tissue-mimicking gels. Any aspects of the field that affect their theoretical description or are important in design are also included. These definitions would have use in scientific communications, system design and description of the performance and safety of systems using these devices.