Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>BS EN IEC 62127-3:2022 Ultrasonics. Hydrophones Properties of hydrophones for ultrasonic fields
Sponsored link
sklademVydáno: 2023-02-02
BS EN IEC 62127-3:2022 Ultrasonics. Hydrophones Properties of hydrophones for ultrasonic fields

BS EN IEC 62127-3:2022

Ultrasonics. Hydrophones Properties of hydrophones for ultrasonic fields

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
7998 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
799.80 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2399.40 Kč
Anglicky Tisk
Skladem
7998 Kč
Označení normy:BS EN IEC 62127-3:2022
Počet stran:38
Vydáno:2023-02-02
ISBN:978 0 539 03740 1
Status:Standard
Popis

BS EN IEC 62127-3:2022


This standard BS EN IEC 62127-3:2022 Ultrasonics. Hydrophones is classified in these ICS categories:
  • 17.140.50 Electroacoustics
IEC 62127-3:2022 is available as IEC 62127-3:2022 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 62127-3:2022 specifies relevant hydrophone characteristics. This document is applicable to: - hydrophones employing piezoelectric sensor elements, designed to measure the pulsed and continuous wave ultrasonic fields generated by ultrasonic equipment; - hydrophones used for measurements made in water; - hydrophones with or without an associated pre-amplifier. IEC 62127-3:2022 cancels and replaces the first edition published in 2007 and Amendment 1:2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition. a) The upper frequency limit of 40 MHz has been removed. b) Hydrophone sensitivity definitions have been changed to recognize sensitivities as complex-valued quantities. c) Procedures to determine the effective hydrophone size have been changed according to the rationale outlined in Annex B. d) Requirements on the frequencies for which the effective hydrophone size shall be provided have been changed to achieve practicality for increased frequency bands. e) The new Annex B and Annex C have been added. f) Annex A has been updated to reflect the changes of the normative parts.