Cena s DPH / bez DPH
Hlavní stránka>BS EN ISO 10121-2:2013 Test methods for assessing the performance of gas-phase air cleaning media and devices for general ventilation Gas-phase air cleaning devices (GPACD)
sklademVydáno: 2013-04-30
BS EN ISO 10121-2:2013 Test methods for assessing the performance of gas-phase air cleaning media and devices for general ventilation Gas-phase air cleaning devices (GPACD)

BS EN ISO 10121-2:2013

Test methods for assessing the performance of gas-phase air cleaning media and devices for general ventilation Gas-phase air cleaning devices (GPACD)

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
8280 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
828.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2484.00 Kč
Anglicky Tisk
Skladem
8280 Kč
Označení normy:BS EN ISO 10121-2:2013
Počet stran:50
Vydáno:2013-04-30
ISBN:978 0 580 69633 6
Status:Standard
Popis

BS EN ISO 10121-2:2013


This standard BS EN ISO 10121-2:2013 Test methods for assessing the performance of gas-phase air cleaning media and devices for general ventilation is classified in these ICS categories:
  • 91.140.30 Ventilation and air-conditioning systems

This part of ISO 10121 aims to provide an objective test method to estimate the performance of any full size gas filtration device (GPACD) for general filtration regardless of media or technique used in the device. In fact, the goal of this part of ISO 10121 is to avoid relating the test data to internal parameters altogether. The benefit with this approach is that customers of GPACDs will be able to concentrate on price/performance and suppliers will have access to a normative and objective test standard that will not require the release of proprietary information or reverse engineering of the product.

To ensure objectivity for test equipment suppliers, no specific design of the test apparatus is specified. Instead requirements of apparatus properties and validation tests are specified. However, different design examples in present use are outlined. This part of ISO 10121 can also be used with technologies such as scrubbers, absorbers, non-sorptive devices or packed columns as long as they fit into the test apparatus, can be meaningfully judged by the test method and are intended for general ventilation applications, both residential and non residential. Nuclear and military applications are specifically excluded.