Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>BS EN ISO 10304-3:1997 Water quality. Determination of dissolved anions by liquid chromatography of ions Determination of chromate, iodide, sulfite, thiocyanate and thiosulfate
Sponsored link
sklademVydáno: 1997-10-15
BS EN ISO 10304-3:1997 Water quality. Determination of dissolved anions by liquid chromatography of ions Determination of chromate, iodide, sulfite, thiocyanate and thiosulfate

BS EN ISO 10304-3:1997

Water quality. Determination of dissolved anions by liquid chromatography of ions Determination of chromate, iodide, sulfite, thiocyanate and thiosulfate

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
6820 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
682.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2046.00 Kč
Anglicky Tisk
Skladem
6820 Kč
Označení normy:BS EN ISO 10304-3:1997
Počet stran:26
Vydáno:1997-10-15
ISBN:0 580 28485 9
Status:Standard
Popis

BS EN ISO 10304-3:1997


This standard BS EN ISO 10304-3:1997 Water quality. Determination of dissolved anions by liquid chromatography of ions is classified in these ICS categories:
  • 13.060.50 Examination of water for chemical substances

This part of ISO 10304 specifies methods for the determination in aqueous solution of the dissolved anions

  • iodide, thiocyanate and thiosulfate (clause 4);

  • sulfite (clause 5);

  • chromate (clause 6).

An appropriate pretreatment of the sample (e.g. dilution) and the application of a conductivity detector (CD), UV detector (UV) or amperometric detector (AD) make the working ranges given in table 1 feasible.

Table 1

Applicable working ranges

Anion Working range1) Detector
Chromate (CrO4), clause 6 0,05 mg/l to 50 mg/l UV (λ = 365 nm)
Iodide (I), clause 4 0,1 mg/l to 50 mg/l CD or UV (λ = 205 nm to 236 nm)
AD (approximately 0,7 V to 1,1 V)
Sulfite (SO3), clause 5 0,1 mg/l to 50 mg/l
0,5 mg/l to 50 mg/l
CD
UV (λ = 205 nm to 220 nm)
Thiocyanate (SCN), clause 4 0,1 mg/l to 50 mg/l CD or UV (λ = 205 nm to 220 nm)
AD (approximately 0,7 V to 1,1 V)
Thiosuifate (S2O3), clause 4 0,1 mg/l to 50 mg/l CD or UV (λ = 205 nm to 220 nm)
AD (approximately 0,7 V to 1,1 V)

1) The working range is restricted by the exchange capacity of the columns. Dilute the sample into the working range if necessary.