Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>BS EN ISO 10497:2022 Testing of valves. Fire type-testing requirements
Sponsored link
sklademVydáno: 2022-11-24
BS EN ISO 10497:2022 Testing of valves. Fire type-testing requirements

BS EN ISO 10497:2022

Testing of valves. Fire type-testing requirements

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
6820 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
682.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2046.00 Kč
Anglicky Tisk
Skladem
6820 Kč
Označení normy:BS EN ISO 10497:2022
Počet stran:28
Vydáno:2022-11-24
ISBN:978 0 539 06533 6
Status:Standard
Popis

BS EN ISO 10497:2022


This standard BS EN ISO 10497:2022 Testing of valves. Fire type-testing requirements is classified in these ICS categories:
  • 23.060.01 Valves in general
  • 13.220.40 Ignitability and burning behaviour of materials and products
This document specifies fire type-testing requirements and a fire type-test method for soft- and metal-seated isolation valves with one or more obturators. It is not applicable to the testing requirements for valve actuators other than manually operated gearboxes or similar mechanisms when these form part of the normal valve assembly. Other types of valve actuators (e.g. electrical, pneumatic or hydraulic) can need special protection to operate in the environment considered in this valve test, and the fire testing of such actuators is outside the scope of this document. This document specifies the measurement and assessment criteria for: a) through-seat leakage; b) external leakage; c) cavity overpressure relief of double-seated valves; d) operability. This document specifies the rules whereby the fire-type testing qualification for a valve can be extended to untested sizes, pressure ratings and materials of construction of the same basic design type. Fire test reports of valves tested according to previous editions of this document are acceptable when submitted together with the full and compliant fire test report as per 6.7 of the edition under which it was tested. Any data missing as required from 6.7 within the fire test report are accepted or rejected at the purchaser’s discretion. NOTE       For the purposes of this document, the terms “fire type-test” and “fire test” are synonymous.