Cena s DPH / bez DPH
Hlavní stránka>BS EN ISO 10993-1:2020 Biological evaluation of medical devices Evaluation and testing within a risk management process
Sponsored link
sklademVydáno: 2020-12-16
BS EN ISO 10993-1:2020 Biological evaluation of medical devices Evaluation and testing within a risk management process

BS EN ISO 10993-1:2020

Biological evaluation of medical devices Evaluation and testing within a risk management process

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
8832 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
883.20 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2649.60 Kč
Anglicky Tisk
Skladem
8832 Kč
Označení normy:BS EN ISO 10993-1:2020
Počet stran:50
Vydáno:2020-12-16
ISBN:978 0 580 94868 8
Status:Standard
Popis

BS EN ISO 10993-1:2020


This standard BS EN ISO 10993-1:2020 Biological evaluation of medical devices is classified in these ICS categories:
  • 11.100.20 Biological evaluation of medical devices
This document specifies: — the general principles governing the biological evaluation of medical devices within a risk management process; — the general categorization of medical devices based on the nature and duration of their contact with the body; — the evaluation of existing relevant data from all sources; — the identification of gaps in the available data set on the basis of a risk analysis; — the identification of additional data sets necessary to analyse the biological safety of the medical device; — the assessment of the biological safety of the medical device. This document applies to evaluation of materials and medical devices that are expected to have direct or indirect contact with: — the patient's body during intended use; — the user's body, if the medical device is intended for protection (e.g., surgical gloves, masks and others). This document is applicable to biological evaluation of all types of medical devices including active, non-active, implantable and non-implantable medical devices. This document also gives guidelines for the assessment of biological hazards arising from: — risks, such as changes to the medical device over time, as a part of the overall biological safety assessment; — breakage of a medical device or medical device component which exposes body tissue to new or novel materials. Other parts of ISO 10993 cover specific aspects of biological assessments and related tests. Device-specific or product standards address mechanical testing. This document excludes hazards related to bacteria, moulds, yeasts, viruses, transmissible spongiform encephalopathy (TSE) agents and other pathogens.