Hlavní stránka>BS EN ISO 11691:2020 Acoustics. Measurement of insertion loss of ducted silencers without flow. Laboratory survey method
Sponsored link
sklademVydáno: 2020-12-02
BS EN ISO 11691:2020 Acoustics. Measurement of insertion loss of ducted silencers without flow. Laboratory survey method

BS EN ISO 11691:2020

Acoustics. Measurement of insertion loss of ducted silencers without flow. Laboratory survey method

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
4898 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
489.80 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1469.40 Kč
Anglicky Tisk
Skladem
4898 Kč
Označení normy:BS EN ISO 11691:2020
Počet stran:18
Vydáno:2020-12-02
ISBN:978 0 539 02095 3
Status:Standard
Popis

BS EN ISO 11691:2020


This standard BS EN ISO 11691:2020 Acoustics. Measurement of insertion loss of ducted silencers without flow. Laboratory survey method is classified in these ICS categories:
  • 91.120.20 Acoustics in building. Sound insulation
  • 91.140.30 Ventilation and air-conditioning systems
  • 17.140.20 Noise emitted by machines and equipment

This document specifies a laboratory substitution method to determine the insertion loss without flow of ducted, mainly absorbent, circular and rectangular silencers, as well as other duct elements for use in ventilating and air-conditioning systems.

NOTE

Laboratory measurement procedures for ducted silencers with superimposed flow are described in ISO 7235 [ 5 ].

This document is applicable to silencers where the design velocity does not exceed 15 m/s. As the method does not include self-generated flow noise, this document is not suitable for tests on silencers where this type of noise is of great importance for the evaluation of the silencer performance. As most silencers, particularly in offices and dwelling, have design velocities below 15 m/s, this document can often be a cost-efficient alternative to ISO 7235[ 5].

The insertion loss determined according to this document in a laboratory is not necessarily the same as the insertion loss obtained in an installation in the field. Different sound and flow fields in the duct yield different results. In this document, the sound field is dominated by plane wave modes. Due to the use of regular test ducts, the results can include some flanking transmission via structural vibrations in the duct walls that sets an upper limit to the insertion loss that can be determined.

This document is intended to be used for circular silencers with diameters of 80 mm to 2 000 mm or for rectangular silencers with cross-sectional areas within the same range.