sklademVydáno: 2017-12-06
BS EN ISO 13260:2011+A1:2017 Thermoplastics piping systems for non-pressure underground drainage and sewerage. Test method for resistance to combined temperature cycling and external loading

BS EN ISO 13260:2011+A1:2017

Thermoplastics piping systems for non-pressure underground drainage and sewerage. Test method for resistance to combined temperature cycling and external loading

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
4898 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
489.80 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1469.40 Kč
Anglicky Tisk
Skladem
4898 Kč
Označení normy:BS EN ISO 13260:2011+A1:2017
Počet stran:18
Vydáno:2017-12-06
ISBN:978 0 580 96374 2
Status:Standard
Popis

BS EN ISO 13260:2011+A1:2017


This standard BS EN ISO 13260:2011+A1:2017 Thermoplastics piping systems for non-pressure underground drainage and sewerage. Test method for resistance to combined temperature cycling and external loading is classified in these ICS categories:
  • 23.040.20 Plastics pipes
  • 93.030 External sewage systems
  • 91.140.80 Drainage systems
  • 23.040.45 Plastics fittings

This International Standard specifies two methods for testing pipes and fittings or joints for plastics piping systems intended for use in underground drainage and sewerage systems for their resistance to deformation and leakage, when subjected to sustained external loading in conjunction with the passage of hot water.

Method A involves temperature cycling, by passing hot water and cold water alternately, and is applicable to pipes and associated fittings having a mean outside diameter d em ≤ 190 mm.

Method B involves passing hot water only, except at intervals specified for measurement of internal deflection, and is applicable to pipes and associated fittings having a mean outside diameter 190 mm <  d em ≤ 510 mm.