Cena s DPH / bez DPH
Hlavní stránka>BS EN ISO 14647:2016 Metallic coatings. Determination of porosity in gold coatings on metal substrates. Nitric acid vapour test
sklademVydáno: 2016-05-31
BS EN ISO 14647:2016 Metallic coatings. Determination of porosity in gold coatings on metal substrates. Nitric acid vapour test

BS EN ISO 14647:2016

Metallic coatings. Determination of porosity in gold coatings on metal substrates. Nitric acid vapour test

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
4500 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
450.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1350.00 Kč
Anglicky Tisk
Skladem
4500 Kč
Označení normy:BS EN ISO 14647:2016
Počet stran:18
Vydáno:2016-05-31
ISBN:978 0 580 90539 1
Status:Standard
Popis

BS EN ISO 14647:2016


This standard BS EN ISO 14647:2016 Metallic coatings. Determination of porosity in gold coatings on metal substrates. Nitric acid vapour test is classified in these ICS categories:
  • 25.220.40 Metallic coatings

This International Standard specifies equipment and a method for using nitric acid vapour to determine porosity in gold coatings, particularly electrodeposits and clad metals used on electrical contacts.

This method is designed to show whether the porosity level is less than or greater than some value that, by experience, is considered by the user to be acceptable for the intended application.

It is suitable for in lays or claddings containing 75% or more of gold, for electro deposits containing 95% or more of gold or for substrates of copper, nickel and their alloys that are commonly used in electrical contacts.

The nitric acid vapour test is too severe to be used for gold coatings less than0,6 µm thick. It is also not suitable for coatings that are less noble than gold or platinum, such as palladium and its alloys, or gold-flashed palladium and its alloys.

Several other porosity testing methods are described in ISO 10308 and in the literature (see e.g. Bibliography,[1] and [2]).


The nitric acid test is not suitable for gold coatings less than 0,6 micrometres thick, for coatings less noble than gold or platinum, or for gold-flashed palladium and its alloys