Cena s DPH / bez DPH
Hlavní stránka>BS EN ISO 15721:2001 Metallic coatings. Porosity tests. Porosity in gold or palladium coatings by sulfurous acid/sulfur dioxide vapour
sklademVydáno: 2001-07-15
BS EN ISO 15721:2001 Metallic coatings. Porosity tests. Porosity in gold or palladium coatings by sulfurous acid/sulfur dioxide vapour

BS EN ISO 15721:2001

Metallic coatings. Porosity tests. Porosity in gold or palladium coatings by sulfurous acid/sulfur dioxide vapour

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
4500 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
450.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1350.00 Kč
Anglicky Tisk
Skladem
4500 Kč
Označení normy:BS EN ISO 15721:2001
Počet stran:20
Vydáno:2001-07-15
ISBN:0 580 37870 5
Status:Standard
Popis

BS EN ISO 15721:2001


This standard BS EN ISO 15721:2001 Metallic coatings. Porosity tests. Porosity in gold or palladium coatings by sulfurous acid/sulfur dioxide vapour is classified in these ICS categories:
  • 25.220.40 Metallic coatings

This test method covers equipment and methods for determining the porosity of gold or palladium coatings, particularly electrodeposits and clad metals used on electrical contacts.

It is designed to show whether the porosity level is less than or greater than a given value which by experience is considered by the user to be acceptable for the intended application.

This porosity test involves corrosion reactions in which the products delineate defect sites in coatings. Since the chemistry and properties of these products may not resemble those found in natural or service environments this test cannot be recommended for the prediction of the electrical performance of contacts unless correlation is first established with service experience.

This test is intended to be used for quantitative descriptions of porosity (such as number of pores per unit area or per contact) on coatings that have a sufficiently low pore density so that the corrosion sites are well separated and can be readily resolved. As a general guideline this can be achieved for pore densities up to about 100/cm2. Above this value the tests are useful for the qualitative detection and comparisons of porosity.

A variety of other porosity testing methods are described in the literature[5],[6]. Other ISO porosity test methods are described ISO 10308, ISO 12687, ISO 14647 and ISO 15720.