Cena s DPH / bez DPH
Hlavní stránka>BS EN ISO 16923:2018 Natural gas fuelling stations. CNG stations for fuelling vehicles
sklademVydáno: 2018-04-30
BS EN ISO 16923:2018 Natural gas fuelling stations. CNG stations for fuelling vehicles

BS EN ISO 16923:2018

Natural gas fuelling stations. CNG stations for fuelling vehicles

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
8700 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
870.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2610.00 Kč
Anglicky Tisk
Skladem
8700 Kč
Označení normy:BS EN ISO 16923:2018
Počet stran:54
Vydáno:2018-04-30
ISBN:978 0 580 99049 6
Status:Standard
Popis

BS EN ISO 16923:2018


This standard BS EN ISO 16923:2018 Natural gas fuelling stations. CNG stations for fuelling vehicles is classified in these ICS categories:
  • 75.200 Petroleum products and natural gas handling equipment

This document covers the design, construction, operation, inspection and maintenance of stations for fuelling compressed natural gas (CNG) to vehicles, including equipment, safety and control devices.

This document also applies to portions of a fuelling station where natural gas is in a gaseous state and dispensing CNG derived from liquefied natural gas (LCNG) according to ISO 16924.

This document applies to fuelling stations supplied with natural gas as defined in local applicable gas composition regulations or ISO 13686. It also applies to other gases meeting these requirements including biomethane, upgraded coal-bed methane (CBM) and gas supplies coming from LNG vaporization (on-site or off-site).

This document includes all equipment for downstream gas supply connection (i.e. point of separation between the CNG fuelling station piping and the pipeline network). Fuelling station nozzles are not defined in this document.

This document covers fuelling stations with the following characteristics:

  • slow fill;

  • fast fill;

  • private access;

  • public access (self-service or assisted);

  • fuelling stations with fixed storage;

  • fuelling stations with mobile storage (daughter station);

  • multi-fuel stations.

This document is not applicable to domestic CNG fuelling devices without buffer storage.

NOTE This document is based on the condition that the gas entering the fuelling station is odorized. For unodorized gas fuelling stations, additional safety requirements are included in Clause 10.