Cena s DPH / bez DPH
Hlavní stránka>BS EN ISO 20685-2:2023 Ergonomics. 3-D scanning methodologies for internationally compatible anthropometric databases Evaluation protocol of surface shape and repeatability of relative landmark positions
Sponsored link
sklademVydáno: 2023-09-21
BS EN ISO 20685-2:2023 Ergonomics. 3-D scanning methodologies for internationally compatible anthropometric databases Evaluation protocol of surface shape and repeatability of relative landmark positions

BS EN ISO 20685-2:2023

Ergonomics. 3-D scanning methodologies for internationally compatible anthropometric databases Evaluation protocol of surface shape and repeatability of relative landmark positions

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
6448 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
644.80 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1934.40 Kč
Anglicky Tisk
Skladem
6448 Kč
Označení normy:BS EN ISO 20685-2:2023
Počet stran:30
Vydáno:2023-09-21
ISBN:978 0 539 20649 4
Status:Standard
Popis

BS EN ISO 20685-2:2023


This standard BS EN ISO 20685-2:2023 Ergonomics. 3-D scanning methodologies for internationally compatible anthropometric databases is classified in these ICS categories:
  • 13.180 Ergonomics
This document establishes protocols for testing of 3-D surface-scanning systems in the acquisition of human body shape data and measurements. It does not apply to instruments that measure the motion of individual landmarks. While mainly concerned with whole-body scanners, this document is also applicable to body-segment scanners (head scanners, hand scanners, foot scanners). It applies to body scanners that measure the human body in a single view. When a hand-held scanner is evaluated, the human operator can contribute to the overall error. When systems are evaluated in which the participant is rotated, movement artefacts can be introduced; these can also contribute to the overall error. This document applies to the landmark positions determined by an anthropometrist. It does not apply to landmark positions automatically calculated by software from the point cloud. The quality of surface shape of the human body and landmark positions is influenced by the performance of scanner systems and humans, including measurers and participants. This document addresses the performance of scanner systems by using artefacts rather than human participants as test objects. Traditional instruments are required to be accurate to the millimetre. Their accuracy can be verified by comparing the instrument with a scale calibrated according to an international standard of length. To verify or specify the accuracy of body scanners, a calibrated test object with known form and size is used. The intended audience is those who use 3-D body scanners to create 3-D anthropometric databases, the users of these data, and body scanner designers and manufacturers. This document intends to provide the basis for agreement on the performance of body scanners between scanner users and scanner providers as well as between 3-D anthropometric database providers and data users.