Cena s DPH / bez DPH
Hlavní stránka>BS EN ISO 21079-1:2008 Chemical analysis of refractories containing alumina, zirconia and silica. Refractories containing 5 percent to 45 percent of ZrO2 (alternative to the X-ray fluorescence method) Apparatus, reagents and dissolution
Sponsored link
sklademVydáno: 2009-04-30
BS EN ISO 21079-1:2008 Chemical analysis of refractories containing alumina, zirconia and silica. Refractories containing 5 percent to 45 percent of ZrO2 (alternative to the X-ray fluorescence method) Apparatus, reagents and dissolution

BS EN ISO 21079-1:2008

Chemical analysis of refractories containing alumina, zirconia and silica. Refractories containing 5 percent to 45 percent of ZrO2 (alternative to the X-ray fluorescence method) Apparatus, reagents and dissolution

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
4650 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
465.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1395.00 Kč
Anglicky Tisk
Skladem
4650 Kč
Označení normy:BS EN ISO 21079-1:2008
Počet stran:20
Vydáno:2009-04-30
ISBN:978 0 580 58570 8
Status:Standard
Popis

BS EN ISO 21079-1:2008


This standard BS EN ISO 21079-1:2008 Chemical analysis of refractories containing alumina, zirconia and silica. Refractories containing 5 percent to 45 percent of ZrO2 (alternative to the X-ray fluorescence method) is classified in these ICS categories:
  • 71.040.40 Chemical analysis
  • 81.080 Refractories

This part of ISO 21079 specifies methods for the chemical analysis of AZS (alumina, zirconia, and silica) refractory products (containing 5 % to 45 % of ZrO2) and raw materials, using traditional (“wet”) methods, inductively coupled plasma atomic emission (ICP-AE) spectrometry and flame atomic absorption (FAA) spectrometry. It covers apparatus, reagents and dissolution methods.

The range of determination is given in Table 1.

Table 1

Range of determination (% by mass)

Component Range Component Range
LOI –1 to 40 MgO 0,01 to 2
SiO2 0,1 to 45 Na2O 0,01 to 3
Al2O3 1 to 80 K2O 0,01 to 1
Fe2O3 0,01 to 2 Cr2O3 0,01 to 3
TiO2 0,01 to 5 ZrO2 5 to 45
CaO 0,01 to 2 HfO2 0,01 to 2

NOTE The values other than LOI are on an ignited basis.

This part of ISO 21079 is not applicable to MgO-based refractories.

NOTE This part of ISO 21079 gives alternatives to the X-ray fluorescence (XRF) method given in ISO 12677.