Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>BS EN ISO 3675:1998 Crude petroleum and liquid petroleum products. Laboratory determination of density. Hydrometer method
Sponsored link
sklademVydáno: 2001-10-25
BS EN ISO 3675:1998 Crude petroleum and liquid petroleum products. Laboratory determination of density. Hydrometer method

BS EN ISO 3675:1998

Crude petroleum and liquid petroleum products. Laboratory determination of density. Hydrometer method

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
4154 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
415.40 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1246.20 Kč
Anglicky Tisk
Skladem
4154 Kč
Označení normy:BS EN ISO 3675:1998
Počet stran:14
Vydáno:2001-10-25
ISBN:0 580 38570 1
Status:Standard
Popis

BS EN ISO 3675:1998


This standard BS EN ISO 3675:1998 Crude petroleum and liquid petroleum products. Laboratory determination of density. Hydrometer method is classified in these ICS categories:
  • 75.200 Petroleum products and natural gas handling equipment

This International Standard specifies a method for the laboratory determination, using a glass hydrometer, of the density at 15°C of crude petroleum, liquid petroleum products, and mixtures of petroleum and non-petroleum products normally handled as liquids and having a Reid vapour pressure (RVP) of 100 kPa or less.

This International Standard is suitable for determining the density of mobile transparent liquids. It can also be used for viscous liquids by carrying out the determinations at temperatures above ambient using a suitable liquid bath for temperature control. It can also be used for opaque liquids by reading the hydrometer scale where the top of the meniscus meets the stem of the hydrometer and applying a correction from table 1 (see 11.2).

Since hydrometers are calibrated to read correctly at the specified temperature, scale readings made at other temperatures are only hydrometer readings and not values of density at these other temperatures.

NOTES

  1. The accuracy of the density, determined by the procedures given in this International Standard, for volatile and/or waxy crude oils containing free and/or suspended water and sediments can be less than inferred from the precision data quoted in clause 13. This is due to the possible loss of light components during sample mixing. However, sample mixing is necessary to ensure that the test portion transferred to the hydrometer cylinder is as representative as possible of the bulk sample. Techniques are given in clause 7 which are designed to minimize such loss of light component.

  2. Values of density at 15 °C can be converted using standard measurement tables to equivalent values of API gravity or relative density so that measurements may be made in the units of local convenience.


Identical with IP 160/99