Cena s DPH / bez DPH
Hlavní stránka>BS EN ISO 5167-6:2022 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Wedge meters
sklademVydáno: 2022-11-07
BS EN ISO 5167-6:2022 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Wedge meters

BS EN ISO 5167-6:2022

Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Wedge meters

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
4500 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
450.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1350.00 Kč
Anglicky Tisk
Skladem
4500 Kč
Označení normy:BS EN ISO 5167-6:2022
Počet stran:22
Vydáno:2022-11-07
ISBN:978 0 539 19496 8
Status:Standard
Popis

BS EN ISO 5167-6:2022


This standard BS EN ISO 5167-6:2022 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full is classified in these ICS categories:
  • 17.120.10 Flow in closed conduits
This document specifies the geometry and method of use (installation and operating conditions) of wedge meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit. NOTE 1    As the uncertainty of an uncalibrated wedge meter can be too large for a particular application, it could be deemed essential to calibrate the flow meter according to Clause 7. This document gives requirements for calibration which, if applied, are for use over the calibrated Reynolds number range. Clause 7 could also be useful guidance for calibration of meters of similar design but which fall outside the scope of this document. It also provides background information for calculating the flow rate and is applicable in conjunction with the requirements given in ISO 5167?1. This document is applicable only to wedge meters in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. Uncalibrated wedge meters can only be used within specified limits of pipe size, roughness, ? (or wedge ratio) and Reynolds number. It is not applicable to the measurement of pulsating flow. It does not cover the use of uncalibrated wedge meters in pipes whose internal diameter is less than 50 mm or more than 600 mm, or where the pipe Reynolds numbers are below 1 × 104. NOTE 2    A wedge meter has a primary element which consists of a wedge-shaped restriction of a specific geometry. Alternative designs of wedge meters are available; however, at the time of writing there is insufficient data to fully characterize these devices, and therefore these meters are calibrated in accordance with Clause 7.