Cena s DPH / bez DPH
Hlavní stránka>BS EN ISO 899-2:2003+A1:2015 Plastics. Determination of creep behaviour Flexural creep by three-point loading
Sponsored link
sklademVydáno: 2015-05-31
BS EN ISO 899-2:2003+A1:2015 Plastics. Determination of creep behaviour Flexural creep by three-point loading

BS EN ISO 899-2:2003+A1:2015

Plastics. Determination of creep behaviour Flexural creep by three-point loading

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
6448 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
644.80 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1934.40 Kč
Anglicky Tisk
Skladem
6448 Kč
Označení normy:BS EN ISO 899-2:2003+A1:2015
Počet stran:24
Vydáno:2015-05-31
ISBN:978 0 580 77080 7
Status:Standard
Popis

BS EN ISO 899-2:2003+A1:2015


This standard BS EN ISO 899-2:2003+A1:2015 Plastics. Determination of creep behaviour is classified in these ICS categories:
  • 83.080.01 Plastics in general

1.1 This part of ISO 899 specifies a method for determining the flexural creep of plastics in the form of standard test specimens under specified conditions such as those of pretreatment, temperature and humidity. It applies only to a simple freely supported beam loaded at mid-span (three-point-loading test).

1.2 The method is suitable for use with rigid and semi-rigid non-reinforced, filled and fibre-reinforced plastics materials (see ISO 472 for definitions) in the form of dumb-bell-shaped test specimens moulded directly or machined from sheets or moulded articles.

NOTE

The method may be unsuitable for certain fibre-reinforced materials due to differences in fibre orientation.

1.3 The method is intended to provide data for engineering-design and research and development purposes. Data for engineering-design purposes requires the use of extensometers to measure the gauge length of the specimen. Data for research or quality-control purposes may use the change in distance between the grips (nominal extension).

1.4 Flexural creep may vary significantly with differences in specimen preparation and dimensions and in the test environment. The thermal history of the test specimen can also have profound effects on its creep behaviour (see Annex A). Consequently, when precise comparative results are required, these factors must be carefully controlled.

1.5 If flexural-creep properties are to be used for engineering-design purposes, the plastics materials should be tested over a broad range of stresses, times and environmental conditions.

1.6 The method may not be suitable for determining the flexural creep of rigid cellular plastics (attention is drawn in this respect to ISO 1209‑1 , Cellular plastics, rigid — Flexural tests — Part 1: Bending test, and ISO 1209‑2 , Cellular plastics, rigid — Flexural tests — Part 2: Determination of flexural properties).