Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>BS EN ISO 9377-2:2000 Water quality. Determination of hydrocarbon oil index Method using solvent extraction and gas chromatography
Sponsored link
sklademVydáno: 2001-10-05
BS EN ISO 9377-2:2000 Water quality. Determination of hydrocarbon oil index Method using solvent extraction and gas chromatography

BS EN ISO 9377-2:2000

Water quality. Determination of hydrocarbon oil index Method using solvent extraction and gas chromatography

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
6820 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
682.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2046.00 Kč
Anglicky Tisk
Skladem
6820 Kč
Označení normy:BS EN ISO 9377-2:2000
Počet stran:30
Vydáno:2001-10-05
ISBN:0 580 36664 2
Status:Standard
Popis

BS EN ISO 9377-2:2000


This standard BS EN ISO 9377-2:2000 Water quality. Determination of hydrocarbon oil index is classified in these ICS categories:
  • 13.060.50 Examination of water for chemical substances

This part of ISO 9377 specifies a method for the determination of the hydrocarbon oil index in waters by means of gas chromatography. The method is suitable for surface water, waste water and water from sewage treatment plants and allows the determination of a hydrocarbon oil index in concentrations above 0,1 mg/l.

The method is not applicable to the quantitative determination of the content of volatile mineral oil. However, on the basis of the peak pattern of the gas chromatogram, certain qualitative information on the composition of the mineral oil contamination can be derived.

NOTE 1 For the determination of the mineral-oil content of soils and sediment, see ISO/TR 11046.

NOTE 2 The mass concentration of animal and vegetable fat in the test sample should not exceed 150 mg/l, because at higher values the adsorption capacity of the clean-up column packing may not be sufficient.

NOTE 3 In the case of highly polluted waste water, especially if containing a high amount of surfactants, a loss in recovery may occur.