Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>BS ISO 18326:2018+A1:2021 Non-ducted portable air-cooled air conditioners and air-to-air heat pumps having a single exhaust duct. Testing and rating for performance
Sponsored link
sklademVydáno: 2021-06-02
BS ISO 18326:2018+A1:2021 Non-ducted portable air-cooled air conditioners and air-to-air heat pumps having a single exhaust duct. Testing and rating for performance

BS ISO 18326:2018+A1:2021

Non-ducted portable air-cooled air conditioners and air-to-air heat pumps having a single exhaust duct. Testing and rating for performance

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
9486 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
948.60 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2845.80 Kč
Anglicky Tisk
Skladem
9486 Kč
Označení normy:BS ISO 18326:2018+A1:2021
Počet stran:60
Vydáno:2021-06-02
ISBN:978 0 539 12530 6
Status:Standard
Popis

BS ISO 18326:2018+A1:2021


This standard BS ISO 18326:2018+A1:2021 Non-ducted portable air-cooled air conditioners and air-to-air heat pumps having a single exhaust duct. Testing and rating for performance is classified in these ICS categories:
  • 23.120 Ventilators. Fans. Air-conditioners
  • 27.080 Heat pumps

This document specifies the standard conditions for capacity and efficiency ratings of non-ducted portable air-cooled air conditioners having a single exhaust duct and non-ducted portable air-cooled heat pumps having a single exhaust duct. Such air conditioners and heat pumps may include an evaporatively cooled condenser cooled by air and the evaporation of:

  1. condensate collected from the evaporator;

  2. external supplementary water stored in a supplementary water tank; or

  3. both a) and b).

This document also specifies the test methods for determining the capacity and efficiency ratings.

This document applies to equipment that is factory-made, electrically driven and uses mechanical compression. This document is applicable to equipment utilizing one or more refrigeration systems.

This document is not applicable to the rating and testing of the following:

  1. Water-source heat pumps or water-cooled air conditioners;

  2. Multi-split-system air conditioners and air-to-air heat pumps (see ISO 15042:2017 for the testing of such equipment);

  3. Individual assemblies not constituting a complete refrigeration system;

  4. Equipment using the absorption refrigeration cycle;

  5. Ducted equipment (see ISO 13253:2017 for the testing of such equipment);

  6. Evaporative coolers or any other cooling systems that are not of the vapour compression type;

  7. Dehumidifiers;

  8. Spot coolers.