Cena s DPH / bez DPH
Hlavní stránka>BS ISO 21439:2009 Clinical dosimetry. Beta radiation sources for brachytherapy
Sponsored link
sklademVydáno: 2009-02-28
BS ISO 21439:2009 Clinical dosimetry. Beta radiation sources for brachytherapy

BS ISO 21439:2009

Clinical dosimetry. Beta radiation sources for brachytherapy

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
9734 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
973.40 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2920.20 Kč
Anglicky Tisk
Skladem
9734 Kč
Označení normy:BS ISO 21439:2009
Počet stran:104
Vydáno:2009-02-28
ISBN:978 0 580 56286 0
Status:Standard
Popis

BS ISO 21439:2009


This standard BS ISO 21439:2009 Clinical dosimetry. Beta radiation sources for brachytherapy is classified in these ICS categories:
  • 17.240 Radiation measurements
  • 11.040.50 Radiographic equipment

This International Standard specifies methods for the determination of absorbed-dose distributions in water or tissue that are required prior to initiating procedures for the application of beta radiation in ophthalmic tumour and intravascular brachytherapy[1], [2], [3]. Recommendations are given for beta radiation source calibration, dosimetry measurements, dose calculation, dosimetric quality assurance, as well as for beta radiation brachytherapy treatment planning. Guidance is also given for estimating the uncertainty of the absorbed dose to water. This International Standard is applicable to “sealed” radioactive sources, such as plane and concave surface sources, source trains of single seeds, line sources, and shell and volume sources, for which only the beta radiation emitted is of therapeutic relevance.

The standardization of procedures in clinical dosimetry described in this International Standard serves as a basis for the reliable application of beta radiation brachytherapy. The specific dosimetric methods described in this International Standard apply to sources for the curative treatment of ophthalmic disease, for intravascular brachytherapy treatment, for overcoming the problem of restenosis and for other clinical applications using beta radiation.

This International Standard is geared towards organizations wishing to establish reference methods in dosimetry aiming at clinical demands for an appropriately small uncertainty of the delivered dose. This International Standard does not exclude the possibility that there can be other methods leading to the same or smaller measurement uncertainties.