Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>BS ISO 21939-1:2019 A method to calculate and express energy consumption of industrial wastewater treatment for the purpose of water reuse Biological processes
Sponsored link
sklademVydáno: 2019-06-06
BS ISO 21939-1:2019 A method to calculate and express energy consumption of industrial wastewater treatment for the purpose of water reuse Biological processes

BS ISO 21939-1:2019

A method to calculate and express energy consumption of industrial wastewater treatment for the purpose of water reuse Biological processes

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
4898 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
489.80 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1469.40 Kč
Anglicky Tisk
Skladem
4898 Kč
Označení normy:BS ISO 21939-1:2019
Počet stran:22
Vydáno:2019-06-06
ISBN:978 0 580 96739 9
Status:Standard
Popis

BS ISO 21939-1:2019


This standard BS ISO 21939-1:2019 A method to calculate and express energy consumption of industrial wastewater treatment for the purpose of water reuse is classified in these ICS categories:
  • 13.060.30 Sewage water
  • 13.060.01 Water quality in general

This document sets out the general principles for, and provides guidance on, the quantitative characterization of the energy consumed by industrial biological wastewater treatment systems. It does not aim to characterize the treatment pollutants removal performance or process reliability or any other consideration in the selection of a wastewater treatment system.

This document includes the following sub-systems of biological treatment system:

  • Biological reactors, which might be suspended growth or fixed film processes or a combination thereof, and can include anaerobic, anoxic and/or aerobic tanks and/or zones.

  • Solid-liquid separation processes such as sedimentation, flotation, or membrane filtration, used for clarification of the water before discharge to downstream processes, which can also involve the return of a the separated solids as sludge back to the biological reactor.

  • Any pumps, blowers and mixers for water circulation, mixing and air supply in and between the sub-systems listed herein.

  • Heating or cooling of the water for treatment.

This document does not include the following subsystems of the biological treatment system:

  • Wastewater feed pumps.

  • Pre-treatment systems, which for the purposes of this document also include preliminary and primary treatment processes, such as but not limited to, screening, sedimentation, dissolved air flotation, chemical oxidation, oil separation.

  • Post-treatment processes, such as but not limited to, disinfection, desalination, ion exchange, sludge treatment and handling systems.

  • Site lighting or any energy consumption involved in office operation.

  • Energy recovery from processes such as anaerobic reactors producing biogas.

Filtration processes, which are sometimes part of the biological treatment process and at other times part of the post treatment, are referred to separately within this document.