Cena s DPH / bez DPH
Hlavní stránka>BS ISO 22104:2021 Water quality. Determination of microcystins. Method using liquid chromatography and tandem mass spectrometry (LC-MS/MS)
Sponsored link
sklademVydáno: 2021-07-07
BS ISO 22104:2021 Water quality. Determination of microcystins. Method using liquid chromatography and tandem mass spectrometry (LC-MS/MS)

BS ISO 22104:2021

Water quality. Determination of microcystins. Method using liquid chromatography and tandem mass spectrometry (LC-MS/MS)

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
7564 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
756.40 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2269.20 Kč
Anglicky Tisk
Skladem
7564 Kč
Označení normy:BS ISO 22104:2021
Počet stran:42
Vydáno:2021-07-07
ISBN:978 0 580 52385 4
Status:Standard
Popis

BS ISO 22104:2021


This standard BS ISO 22104:2021 Water quality. Determination of microcystins. Method using liquid chromatography and tandem mass spectrometry (LC-MS/MS) is classified in these ICS categories:
  • 13.060.50 Examination of water for chemical substances

This document specifies a method for the quantification of twelve microcystin variants (microcystin-LR, -LA, -YR, -RR, -LY, -WR, -HtyR, -HilR, -LW, -LF, [Dha7]-microcystin-LR, and [Dha7]-microcystin-RR) in drinking water and freshwater samples between 0,05 µg/l to 1,6 µg/l. The method can be used to determine further microcystins, provided that analytical conditions for chromatography and mass spectrometric detection has been tested and validated for each microcystin. Samples are analysed by LC-MS/MS using internal standard calibration.

This method is performance based. The laboratory is permitted to modify the method, e.g. increasing direct flow injection volume for low interference samples or diluting the samples to increase the upper working range limit, provided that all performance criteria in this method are met.

Detection of microcystins by high resolution mass spectrometry (HRMS) as an alternative for tandem mass spectrometry (MS/MS) is described in Annex A.

An alternative automated sample preparation method based on on-line solid phase extraction coupled to liquid chromatography is described in Annex B.

When instrumental sensitivity is not sufficient to reach the method detection limits by direct flow injection, a solid phase extraction clean-up and concentration step is described in Annex C.