Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>BS ISO 30011:2010 Workplace air. Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma mass spectrometry
Sponsored link
sklademVydáno: 2011-01-31
BS ISO 30011:2010 Workplace air. Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma mass spectrometry

BS ISO 30011:2010

Workplace air. Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma mass spectrometry

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
8990 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
899.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2697.00 Kč
Anglicky Tisk
Skladem
8990 Kč
Označení normy:BS ISO 30011:2010
Počet stran:46
Vydáno:2011-01-31
ISBN:978 0 580 58962 1
Status:Standard
Popis

BS ISO 30011:2010


This standard BS ISO 30011:2010 Workplace air. Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma mass spectrometry is classified in these ICS categories:
  • 13.040.30 Workplace atmospheres

This International Standard specifies a procedure for the use of quadrupole inductively coupled plasma mass spectrometry (ICP-MS) for analysing test solutions prepared from samples of airborne particulate matter collected as specified in ISO 15202-1. Method development, performance checks, and a routine analysis method are specified.

Test solutions for analysis by this International Standard are prepared as specified in ISO 15202-2.

This International Standard is applicable to the assessment of workplace exposure to metals and metalloids for comparison with limit values (see e.g. EN 689[10], ASTM E1370[8]).

The following is a non-exclusive list of metals and metalloids for which limit values have been set (see Reference [15]) and for which one or more of the sample preparation methods specified in ISO 15202-2 and the analytical procedure described in this International Standard are applicable. However, there is no information available on the effectiveness of any of these sample preparation methods for those elements listed in italics.

aluminium caesium lead platinum tungsten
antimony chromium lithium potassium uranium
arsenic cobalt magnesium rhodium vanadium
barium copper manganese selenium yttrium
beryllium gallium mercury silver zinc
bismuth germanium molybdenum sodium zirconium
boron hafnium nickel tellurium  
cadmium indium niobium thallium  
calcium iron phosphorus tin  

This International Standard is not applicable to determination of elemental mercury, since mercury vapour is not collected using the sampling method specified in ISO 15202-1.

The procedure is suitable for assessment of exposure against the long-term exposure limits for most of the metals and metalloids listed above when sampling at a typical flow rate of 2 l min−1 for sampling times in the range 0,5 h to 8 h and for assessment of exposure against the short-term exposure limits, where applicable.

The procedure is subject to no significant spectral interferences (see A.3), provided that suitable analytical isotopes are used. However, inadequate matrix-matching can adversely affect results.