Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Cena s DPH / bez DPH
Hlavní stránka>BS ISO 30021:2013 Plastics. Burning behavior. Intermediate-scale fire-resistance testing of fibre-reinforced polymer composites
Sponsored link
sklademVydáno: 2013-09-30
BS ISO 30021:2013 Plastics. Burning behavior. Intermediate-scale fire-resistance testing of fibre-reinforced polymer composites

BS ISO 30021:2013

Plastics. Burning behavior. Intermediate-scale fire-resistance testing of fibre-reinforced polymer composites

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
4898 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
489.80 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1469.40 Kč
Anglicky Tisk
Skladem
4898 Kč
Označení normy:BS ISO 30021:2013
Počet stran:18
Vydáno:2013-09-30
ISBN:978 0 580 73918 7
Status:Standard
Popis

BS ISO 30021:2013


This standard BS ISO 30021:2013 Plastics. Burning behavior. Intermediate-scale fire-resistance testing of fibre-reinforced polymer composites is classified in these ICS categories:
  • 13.220.40 Ignitability and burning behaviour of materials and products
  • 83.080.01 Plastics in general

This International Standard specifies a method of determining the fire resistance of non-load-bearing separating elements made of fibre reinforced plastics (FRP) when exposed to heating on one face.

It is applicable to FRP products for which the end-use application is smaller than the full-scale fire test specimen specified in ISO 834-1. Fire barriers in transportation applications are a common example, since the end-use dimensions of the barrier products are often smaller than those specified in ISO 834-1.

This test is, in general, applicable to FRP products which have an essentially flat surface and can have stiffening members. This includes sandwich-panel-type structures in which the skins consist of FRP.

CAUTION — The attention of all persons concerned with managing and carrying out this fire-resistance test is drawn to the fact that fire testing is hazardous and there is a possibility of toxic and/or harmful smoke and gases being evolved during the test. Mechanical and operational hazards can also arise during the construction of the test elements or structures, their testing and disposal of test residues.

It is essential that an assessment of all potential hazards and risks to health is made and safety precautions are identified and provided. It is also essential that written safety instructions are issued, that appropriate training is given to relevant personnel and that laboratory personnel ensure that they follow written safety instructions at all times.