Cena s DPH / bez DPH
Hlavní stránka>BS ISO 532-1:2017 Acoustics. Methods for calculating loudness Zwicker method
Sponsored link
sklademVydáno: 2018-09-25
BS ISO 532-1:2017 Acoustics. Methods for calculating loudness Zwicker method

BS ISO 532-1:2017

Acoustics. Methods for calculating loudness Zwicker method

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
8990 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
899.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2697.00 Kč
Anglicky Tisk
Skladem
8990 Kč
Označení normy:BS ISO 532-1:2017
Počet stran:66
Vydáno:2018-09-25
ISBN:978 0 539 01987 2
Status:Standard
Popis

BS ISO 532-1:2017


This standard BS ISO 532-1:2017 Acoustics. Methods for calculating loudness is classified in these ICS categories:
  • 17.140.01 Acoustic measurements and noise abatement in general

This document specifies two methods for estimating the loudness and loudness level of sounds as perceived by otologically normal persons under specific listening conditions. The first method is intended for stationary sounds and the second method for arbitrary non-stationary (time-varying) sounds, including stationary sounds as a special case.

The methods can be applied to any sound recorded as single-channel measurements using a microphone, or as multi-channel measurements, for example by means of a head and torso simulator (see Annex D). Since most important technical sounds are time-varying, a model of time-varying loudness is preferable.

The methods are based on the Zwicker algorithm.[14] The method for stationary sounds is provided for reasons of continuity and also offers the use of measured one-third-octave-band levels as input. The more general method for arbitrary sounds calculates the specific loudness pattern based on measured time signals by applying a signal processing model that is directly related to physiological and psychological characteristics of the human hearing system. Loudness is calculated from the specific loudness pattern. It has been shown that this method provides a good match to the results of many loudness experiments using synthetic and technical sounds.

No prior knowledge about the properties of the sound (e.g. broadband or narrowband noise, tonal content) and no user interactions are required for the fully automated application of the method.

The evaluation of the harmful effect of sound events is outside the scope of this document.