Cena s DPH / bez DPH
Hlavní stránka>BS ISO 6721-11:2019 Plastics. Determination of dynamic mechanical properties Glass transition temperature
Sponsored link
sklademVydáno: 2019-12-20
BS ISO 6721-11:2019 Plastics. Determination of dynamic mechanical properties Glass transition temperature

BS ISO 6721-11:2019

Plastics. Determination of dynamic mechanical properties Glass transition temperature

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
6448 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
644.80 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
1934.40 Kč
Anglicky Tisk
Skladem
6448 Kč
Označení normy:BS ISO 6721-11:2019
Počet stran:24
Vydáno:2019-12-20
ISBN:978 0 580 52278 9
Status:Standard
Popis

BS ISO 6721-11:2019


This standard BS ISO 6721-11:2019 Plastics. Determination of dynamic mechanical properties is classified in these ICS categories:
  • 83.080.01 Plastics in general

This document specifies methods for determining a value of the glass transition temperature (Tg) from the dynamic mechanical properties measured during a linear temperature scan under heating conditions. The glass transition temperature is an indicator of the transition from a hard and relatively brittle glassy state to a rubbery or viscous liquid state in an amorphous polymer or in amorphous regions of a partially crystalline polymer.

Usually referred to as dynamic mechanical analysis (DMA), the methods and their associated procedures can be applied to unreinforced and filled polymers, foams, rubbers, adhesives and fibre-reinforced plastics/composites. The methods are limited to materials that are inherently stable above Tg, i.e. amorphous materials that transform into a rubbery state or partially crystalline materials that keep their shape due to crystallinity.

Different modes (e.g. flexure, torsion, shear, compression, tension) of dynamic mechanical analysis can be applied, as appropriate, to the form of the source material.

Measured Tg values using instrumentation can vary as a result of material characteristics and/or the test set-up. The temperature sensor in a DMA instrument is not in contact with the test specimen and therefore measures temperature of the environment surrounding the specimen under test. The resulting data can vary with the heating rate applied. A procedure is included to take into account the thermal lag influencing the measured data.