Cena s DPH / bez DPH
Hlavní stránka>BS ISO 7194:2008 Measurement of fluid flow in closed conduits. Velocity-area methods of flow measurement in swirling or asymmetric flow conditions in circular ducts by means of current-meters or Pitot statics tubes
Sponsored link
sklademVydáno: 2008-08-31
BS ISO 7194:2008 Measurement of fluid flow in closed conduits. Velocity-area methods of flow measurement in swirling or asymmetric flow conditions in circular ducts by means of current-meters or Pitot statics tubes

BS ISO 7194:2008

Measurement of fluid flow in closed conduits. Velocity-area methods of flow measurement in swirling or asymmetric flow conditions in circular ducts by means of current-meters or Pitot statics tubes

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
7564 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
756.40 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2269.20 Kč
Anglicky Tisk
Skladem
7564 Kč
Označení normy:BS ISO 7194:2008
Počet stran:38
Vydáno:2008-08-31
ISBN:978 0 580 62862 7
Status:Standard
Popis

BS ISO 7194:2008


This standard BS ISO 7194:2008 Measurement of fluid flow in closed conduits. Velocity-area methods of flow measurement in swirling or asymmetric flow conditions in circular ducts by means of current-meters or Pitot statics tubes is classified in these ICS categories:
  • 17.120.10 Flow in closed conduits

This International Standard specifies velocity-area methods for measuring flow in swirling or asymmetric flow conditions in circular ducts by means of current-meters or Pitot static tubes.

It specifies the measurements required, the precautions to be taken, the corrections to apply, and describes the additional uncertainties which are introduced when a measurement in asymmetric or swirling flow has to be made.

Only flows with a negligible radial component are considered, however. Furthermore, it is not possible to make a measurement in accordance with this International Standard if, at any point in the measuring cross-section, the local velocity makes an angle of greater than 40° with the axis of the duct, or where the index of asymmetry Y (defined in Annex F) is greater than 0,15.

This International Standard deals only with instruments for measuring local velocity as defined in ISO 3354 and ISO 3966. If Pitot static tubes are used, this International Standard applies only to flows where the Mach number corresponding to local velocities does not exceed 0,25.