Cena s DPH / bez DPH
Hlavní stránka>BS ISO/IEC 10192-3:2017 Information technology. Home electronic system (HES) interfaces Modular communications interface for energy management
sklademVydáno: 2018-01-05
BS ISO/IEC 10192-3:2017 Information technology. Home electronic system (HES) interfaces Modular communications interface for energy management

BS ISO/IEC 10192-3:2017

Information technology. Home electronic system (HES) interfaces Modular communications interface for energy management

Formát
Dostupnost
Cena a měna
Anglicky Zabezpečené PDF
K okamžitému stažení
9420 Kč
Čtěte normu po dobu 1 hodiny. Více informací v kategorii E-READING
Čtení normy
na 1 hodinu
942.00 Kč
Čtěte normu po dobu 24 hodin. Více informací v kategorii E-READING
Čtení normy
na 24 hodin
2826.00 Kč
Anglicky Tisk
Skladem
9420 Kč
Označení normy:BS ISO/IEC 10192-3:2017
Počet stran:100
Vydáno:2018-01-05
ISBN:978 0 580 90963 4
Status:Standard
Popis

BS ISO/IEC 10192-3:2017


This standard BS ISO/IEC 10192-3:2017 Information technology. Home electronic system (HES) interfaces is classified in these ICS categories:
  • 35.240.99 IT applications in other fields
  • 35.200 Interface and interconnection equipment

This part of IEC 10192 specifies a UCM (Universal Communications Module) that transfers energy management data via a home network between an end-device and an energy management agent (specified in ISO/IEC 15067‑3) or an energy service provider. This document specifies the mechanical, electrical and logical characteristics of the interfaces of UCM to an end-device (hereafter referred to as an SGD — Smart Grid Device) and a choice of interfaces to a home communications network.

This document specifies the physical and data-link characteristics of the interface between the UCM and the SGD, along with certain higher-layer and application layer elements as needed to assure interoperability over a broad range of device capabilities. It specifies a mechanism through which network, transport and application layer messages specified in other documents listed in this document may be passed through the interface. For those end-devices that cannot process one of the “pass-through” command sets, a Simple Protocol is specified according to the OSI (Open System Interconnect) reference model (ISO/IEC 7498‑1) including application layer messaging for energy management.

The UCM specified in this document is intended to be installable by the purchaser, home occupant or professional installer. The connectors are integrated in a way that allows for easy, plug-in installation. However, the manufacturer may choose to pre-install a module during production or have installation handled by a manufacturer representative or professional installer.

The scope of this document does not include safety related construction, performance, marking or instruction requirements. UCM products should additionally comply with applicable product safety standard(s). Examples of such standards are presented in Annex G.

NOTE Some regulatory authorities require that appliances intended for participation in energy management, such as thermostats, be user installable.