S účinností od 2024-04-02 se nahrazuje ČSN EN 62053-22 (35 6132) z prosince 2003, která do uvedeného data platí souběžně s touto normou.
Označení normy: | ČSN EN IEC 62053-22 ed. 2 |
Třídící znak: | 356132 |
Počet stran: | 28 |
Vydáno: | 01.08.2021 |
Harmonizace: | Norma není harmonizována |
Katalogové číslo: | 511759 |
Popis
ČSN EN IEC 62053-22 ed. 2
This part of IEC 62053 applies only to transformer operated static watt-hour meters of accuracy classes 0,1 S, 0,2 S and 0,5 S for the measurement of alternating current electrical active energy in 50 Hz or 60 Hz networks and it applies to their type tests only. NOTE 1 - For other general requirements, such as safety, dependability, etc., see the relevant IEC 62052 or IEC 62059 standards. This document applies to electricity metering equipment designed to: 1. measure and control electrical energy on electrical networks (mains) with voltage up to 1 000 V; NOTE 2 - For AC electricity meters, the voltage mentioned above is the line-to-neutral voltage derived from nominal voltages. See IEC 62052-31:2015, Table 7. 2. have all functional elements, including add-on modules, enclosed in, or forming a single meter case with exception of indicating displays; 3. operate with integrated or detached indicating displays, or without an indicating display; 4. be installed in a specified matching socket or rack; 5. optionally, provide additional functions other than those for measurement of electrical energy. NOTE 3 - Modern electricity meters typically contain additional functions such as measurement of voltage magnitude, current magnitude, power, frequency, power factor, etc.; measurement of power quality parameters; load control functions; delivery, time, test, accounting, recording functions; data communication interfaces and associated data security functions. The relevant standards for these functions may apply in addition to the requirements of this document. However, the requirements for such functions are outside the scope of this document. NOTE 4 - Product requirements for power metering and monitoring devices (PMDs) and measurement functions such as voltage magnitude, current magnitude, power, frequency, etc., are covered in IEC 61557-12. However, devices compliant with IEC 61557-12 are not intended to be used as billing meters unless they are also compliant with the IEC 62052-11:2020 and one or more relevant IEC 62053-xx accuracy class standards. NOTE 5 - Product requirements for power quality instruments (PQIs) are covered in IEC 62586-1. Requirements for power quality measurement techniques (functions) are covered in IEC 61000-4-30. Requirements for testing of the power quality measurement functions are covered in IEC 62586-2.Změny norem
Anglicky Tisk
Skladem
86 Kč