Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS 1042-2.2:1983 Measurement of fluid flow in closed conduits. Velocity area methods Method of measurement of velocity at one point of a conduit of circular cross section
Sponsored link
sklademVydáno: 1983-08-31
BS 1042-2.2:1983 Measurement of fluid flow in closed conduits. Velocity area methods Method of measurement of velocity at one point of a conduit of circular cross section

BS 1042-2.2:1983

Measurement of fluid flow in closed conduits. Velocity area methods Method of measurement of velocity at one point of a conduit of circular cross section

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
183.58 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
18.36 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
55.07 €
Anglicky Hardcopy
In stock
183.58 €
Označení normy:BS 1042-2.2:1983
Počet stran:20
Vydáno:1983-08-31
ISBN:0 580 13383 4
Status:Standard
DESCRIPTION

BS 1042-2.2:1983


This standard BS 1042-2.2:1983 Measurement of fluid flow in closed conduits. Velocity area methods is classified in these ICS categories:
  • 17.120.10 Flow in closed conduits

This International Standard specifies a method for the determination of the volume rate of flow of a single phase fluid of a substantially constant density (Mach number ≤ 0,25) under steady fully developed flow conditions in a closed conduit of circular cross-section running full by measurement of the flow velocity in a single point.

The method provides for the possibility of placing the primary velocity measuring device either at the point where it is assumed the mean axial velocity prevails, i.e. at a distance of 0,242 R from the wall of the conduit (R being the radius of the conduit), or on the axis of the conduit.

If there are doubts about the symmetry of the flow it is advisable to use at least two measuring points located symmetrically on one circumference at the distance from the wall specified above.

If there are doubts about the symmetry of the flow it is advisable to use at least two measuring points located symmetrically on one circumference at the distance from the wall specified above.

1.2 Field of application

The method specified in this International Standard does not apply unless the following conditions have been fulfilled:

  1. The conduit shall have a straight length sufficiently long so that, in the measuring section, a distribution of velocities corresponding to fully developed turbulent flow can be observed (see 2.3.5).

    Hydraulic resistance coefficient λ of the conduit should not exceed 0,06.

  2. The flow must be turbulent and the Reynolds number, ReD' should exceed or be equal to the following values:
λ ≥ 0,03 0,025 0,02 0,01
ReD 104 3 × 104 105 106

When the velocity is measured on the conduit axis, the flow should be in fully rough turbulent regime (see 2.3.6). The Reynolds number, ReD, should then exceed or be equal to:

λ 0,06 0,05 0,04 0,03 0,025 0,02 0,01
ReD 3 × 104 5 × 104 105 3 × 105 5 × 105 106 5 × 107
  1. The experimental data on which this International Standard is based principally relate to conduits of diameter equal to or greater than 300 mm, but there is every reason to believe that the method can be applied to conduits of smaller diameter.
  2. In any point of the measuring cross-section, the angle between the direction of local velocity and the axis should not exceed 5°.

This condition can be verified either with the probe used for the measurements, if the design permits this, or with a different type of probe. It can be assumed that if the condition required is verified for a given flow q, then this condition is also met within the range q/3 to 3q.

1.3 Accuracy of the method

As a guide, it can be considered that determination of flow from velocity measurement at a single point, carried out in accordance with the requirements of this International Standard, will lead to an uncertainty (at a confidence level of 95 %) not exceeding ± 3 %. However, the uncertainty on the flow shall be calculated for each individual application of this International Standard depending on the type of primary device, on the method of use and if necessary, on the method of calibration as well as on the measuring conditions.


Gives a method of determining the volume rate of flow of a single phase fluid of a substantially constant density (Mach no ≤0.25) under steady fully developed flow conditions in a closed conduit of circular cross section running full, by measurement of the flow velocity at a single point.