Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS 2G 232:1987 Specification for electric cables for general airframe or equipment interconnect use (135°C), wrapped insulation
sklademVydáno: 1987-09-30
BS 2G 232:1987 Specification for electric cables for general airframe or equipment interconnect use (135°C), wrapped insulation

BS 2G 232:1987

Specification for electric cables for general airframe or equipment interconnect use (135°C), wrapped insulation

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
177.34 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
17.73 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
53.20 €
Anglicky Hardcopy
In stock
177.34 €
Označení normy:BS 2G 232:1987
Počet stran:22
Vydáno:1987-09-30
ISBN:0 580 15920 5
Status:Standard
DESCRIPTION

BS 2G 232:1987


This standard BS 2G 232:1987 Specification for electric cables for general airframe or equipment interconnect use (135°C), wrapped insulation is classified in these ICS categories:
  • 49.060 Aerospace electric equipment and systems

This British Standard specifies construction and performance requirements for a range of lightweight cables with wrapped insulation suitable for general airframe use in the size range 26 to 0000, and for equipment interconnect in the size range 26 to 18.

The following types of cable are specified.

00172043_img1

The cables are suitable for continuous use where the maximum stabilized conductor temperature does not exceed 135 °C. They are suitable for applications involving flexing at temperatures down to – 65 °C. The cables are suitable for use where the potential between conductors or between a conductor and screen, or the aircraft structure, does not exceed 600 V r.m.s. and the frequency does not exceed 2 000 Hz.

Interconnect cables are suitable for use in areas with some physical protection, such as behind panels or bulkheads. They also have an application for the internal wiring of equipment.

Airframe cables are of sufficiently robust construction to be used for open aircraft wiring.

The short-term and long-term current ratings for the cables are specified in this standard.

NOTE The titles of the publications referred to in this standard are listed on the inside back cover.


Specifies the construction and performance requirements for a range of lightweight cables with wrapped insulation suitable for general airframe use in the size range 26 to 0000, and for equipment interconnect in the size range 26 to 18.