Homepage>BS 5724-2.15:1989 Medical electrical equipment. Particular requirements for safety Specification for capacitor discharge X-ray generators
Sponsored link
sklademVydáno: 1989-10-31
BS 5724-2.15:1989 Medical electrical equipment. Particular requirements for safety Specification for capacitor discharge X-ray generators

BS 5724-2.15:1989

Medical electrical equipment. Particular requirements for safety Specification for capacitor discharge X-ray generators

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
318.39 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
31.84 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
95.52 €
Anglicky Hardcopy
In stock
318.39 €
Označení normy:BS 5724-2.15:1989
Počet stran:34
Vydáno:1989-10-31
ISBN:0 580 17627 4
Status:Standard
DESCRIPTION

BS 5724-2.15:1989


This standard BS 5724-2.15:1989 Medical electrical equipment. Particular requirements for safety is classified in these ICS categories:
  • 11.040.50 Radiographic equipment
  • 13.280 Radiation protection

Addition:

This Particular Standard applies to capacitor discharge X-ray generators operating in intermittent mode for medical radiography, in which the electrical energy for loading of the X-ray tube is completely or mainly capacitively stored at, and switched in, the high-voltage circuit.

This Particular Standard is confined to those devices which are medical electrical equipment and in which

  • the storage capacitor is in the high-voltage circuit and has a specified capacitance not exceeding 2 μF,

  • the initial X-ray tube voltage is between 40 kV and 150 kV,

  • an overcurrent protection, if provided, would not require a rating exceeding that which corresponds to an apparent power of 3 kVA,

  • LOADING of the X-ray TUBE is controlled in the high-voltage circuit.

This Particular Standard does not exclude capacitor discharge X-ray generators that are capable of operation in continuous mode for direct radioscopy or indirect radioscopy. However, for this mode of operation the device will have to comply with the relevant requirements for diagnostic high-voltage generators and diagnostic X-ray equipment (see Sub-clause 1.3.102).


X-ray generators, in which electrical energy for loading is completely or mainly stored and switched capacitively, and in which the storage capacitor does not exceed 2GmF and the tube voltage is 40 kV to 150 kV.