Sponsored link
sklademVydáno: 2015-01-31
BS 5918:2015 Solar heating systems for domestic hot water. Code of practice for design and installation

BS 5918:2015

Solar heating systems for domestic hot water. Code of practice for design and installation

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
407.25 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
40.73 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
122.18 €
Anglicky Hardcopy
In stock
407.25 €
Označení normy:BS 5918:2015
Počet stran:74
Vydáno:2015-01-31
ISBN:978 0 580 61963 2
Status:Standard
DESCRIPTION

BS 5918:2015


This standard BS 5918:2015 Solar heating systems for domestic hot water. Code of practice for design and installation is classified in these ICS categories:
  • 27.160 Solar energy engineering
  • 97.100.99 Heaters using other sources of energy

This British Standard gives recommendations and guidance for the installation of common indirect solar domestic hot water (SDHW) systems for all types of building in the UK. It includes recommendations and guidance for design, handling, installation, commissioning, handover, maintenance, decommissioning and fault-finding.

NOTE 1 SDHW is domestic hot water (DHW) that has intentionally received heat derived from solar radiation via a solar collector.

The standard covers systems:

  1. in which solar radiation is converted to heat that is primarily intended for domestic hot water preparation;

  2. that contain solar collector(s) intended to transfer heat using an aqueous-based liquid medium;

  3. whose solar collectors conform to BS EN 12975‑1 and BS EN ISO 9806;

  4. which contain collectors that provide up to 20 kW instantaneous peak power output measured leaving the collector, when tested in accordance with BS EN ISO 9806 at 800 W/m2 perpendicular to the collector aperture plane;

    NOTE 2 Depending on the characteristics of the system, this typically equates to a gross collector area of up to approximately 30 m2.

  5. in which heat is primarily stored in aqueous-based liquid media; and

  6. in which the primary circuit is indirect with a heat exchanger that is internal to the solar storage vessel and which separates the primary heat transfer fluid that passes through the collector from the DHW.

This British Standard does not cover:

  1. applications that are primarily intended to provide heat for applications such as space heating, cooling or swimming pools and any other than DHW preparation;

  2. solar primary system layouts that use solar storage vessels that are outside the building;

  3. solar primary system layouts with multiple collector fields;

  4. DHW systems that comprise multiple solar or multiple DHW storage vessels; or

  5. solar primary system layouts that incorporate a heat pump or other device that utilizes the Carnot cycle.

NOTE 3 It is assumed in the calculations in this British Standard that there is user-disinterest in the DHW settings, i.e. that default factory timer and thermostat settings are present. Extra heating required for bacterial disinfection is not assumed in these calculations.

NOTE 4 Where stated in the standard, the pressure is that exceeding atmospheric pressure at sea level.