Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS 6068-2.17:1986 Water quality. Physical, chemical and biochemical methods Methods for determination of total cyanide
Sponsored link
sklademVydáno: 1986-02-28
BS 6068-2.17:1986 Water quality. Physical, chemical and biochemical methods Methods for determination of total cyanide

BS 6068-2.17:1986

Water quality. Physical, chemical and biochemical methods Methods for determination of total cyanide

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
183.40 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
18.34 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
55.02 €
Anglicky Hardcopy
In stock
183.40 €
Označení normy:BS 6068-2.17:1986
Počet stran:18
Vydáno:1986-02-28
ISBN:0 580 14987 0
Status:Standard
DESCRIPTION

BS 6068-2.17:1986


This standard BS 6068-2.17:1986 Water quality. Physical, chemical and biochemical methods is classified in these ICS categories:
  • 13.060.50 Examination of water for chemical substances

This Section of this British Standard specifies three methods for the determination of total cyanide (see clause 2) in water.

The methods are applicable to water containing less than 100 mg of cyanide per litre, but higher concentrations may be determined by suitable dilution of the sample.

The methods and corresponding ranges of cyanide contents for which they are suitable are as follows:

  • Photometric method with pyridine/barbituric acid: applicable when the absorption solution contains 0,002 to 0,025 mg of cyanide, corresponding to 0,02 to 0,25 mg/l in a 100 ml aliquot portion of the undiluted sample;
  • Titrimetric method using the Tyndall effect: applicable when the absorption solution contains > 0,005 mg of cyanide, corresponding to > 0,05 mg/l in a 100 ml aliquot portion of the undiluted sample;
  • Titrimetric method using an indicator, applicable when the absorption solution contains > 0,05 mg of cyanide, corresponding to > 0,5 mg/l in a 100 ml aliquot portion of the undiluted sample.

A large number of ions and compounds interfere with the determination. These are listed in the Table 1, together with the concentrations below which they do not interfere (the list is not exhaustive). If present singly or in combination, up to the limiting concentrations, they do not interfere with the separation of hydrogen cyanide. The presence of aldehydes, e.g. formaldehyde, causes low cyanide values because of the formation of cyanohydrin.

If any of the limiting concentrations of the interferences is likely to be exceeded, the sample shall be diluted with distilled water before stabilization (see clause 6).

Other interference may arise from the presence of fatty acids, which will distil and form soaps during titration of alkaline solution, and from the presence of elementary sulfur.


Three methods for concentrations of up to 100 mg/l in water: a photometric method with pyridine/barbituric acid, a titrimetric method using the Tyndall effect and a titrimetric method using an indicator.