Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS 6993-2:1990 Thermal and radiometric properties of glazing Method for direct measurement of U-value (thermal transmittance)
Sponsored link
sklademVydáno: 1990-07-31
BS 6993-2:1990 Thermal and radiometric properties of glazing Method for direct measurement of U-value (thermal transmittance)

BS 6993-2:1990

Thermal and radiometric properties of glazing Method for direct measurement of U-value (thermal transmittance)

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
154.05 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
15.41 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
46.22 €
Anglicky Hardcopy
In stock
154.05 €
Označení normy:BS 6993-2:1990
Počet stran:14
Vydáno:1990-07-31
ISBN:0 580 17934 6
Status:Standard
DESCRIPTION

BS 6993-2:1990


This standard BS 6993-2:1990 Thermal and radiometric properties of glazing is classified in these ICS categories:
  • 81.040.20 Glass in building

This Part of BS 6993 describes a method for measuring the U-value (thermal transmittance) of the central area of single, double or multiple glazing using hot-box apparatus complying with BS 874-3.1. The edge effect, due to the thermal bridge through the spacer of double or multiple glazing, is effectively eliminated in this method.

The method is designed to measure the U-value of the glazing alone, i.e. the glass (or alternative glazing material) and any enclosed air space, and the additional information required in the test reports of clause 8 and A.9 of BS 874-3.1:1987.

Appendix A specifies values to be used in the calculation of a U-value in accordance with BS 6993-1, when such a calculated value is to be compared with that obtained by direct measurement in accordance with this Part of BS 6993.

Appendix A gives a worked example, which illustrates the use of this Part of BS 6993.

NOTE The titles of the publications referred to in this standard are listed on the inside back cover.


Method for measuring the transmittance of the central area of single, double or multiple glazing using hot box apparatus complying with BS 874-3.1. The edge effect due to the thermal bridge through the spacer of double or multiple glazing is effectively eliminated by this method.