BS 7346-4:2003 Components for smoke and heat control systems Functional recommendations and calculation methods for smoke and heat exhaust ventilation systems, employing steady-state design fires. Code of practice

BS 7346-4:2003

Components for smoke and heat control systems Functional recommendations and calculation methods for smoke and heat exhaust ventilation systems, employing steady-state design fires. Code of practice

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
383.91 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
38.39 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
115.17 €
Anglicky Hardcopy
In stock
383.91 €
Označení normy:BS 7346-4:2003
Počet stran:90
Vydáno:2003-08-23
ISBN:0 580 42233 X
Status:Standard
DESCRIPTION

BS 7346-4:2003


This standard BS 7346-4:2003 Components for smoke and heat control systems is classified in these ICS categories:
  • 13.220.20 Fire protection

This part of BS 7346 gives recommendations and guidance on functional and calculation methods for smoke and heat exhaust ventilation systems for steady-state design fires. It is intended for a variety of building types and applications, including single-storey buildings, mezzanine floors, warehouses with palletized or racked storage, shopping malls, atria and complex buildings, car parks, places of entertainment and public assembly and uncompartmented space within multi-storey buildings.

This standard does not include any functional recommendations for design parameters where the primary purpose of the SHEVS is to assist fire-fighting.

NOTE Such functional recommendations need to be agreed with the fire service responsible for the building in question. The calculation procedures set out in the annexes of this document can be used to design the SHEVS to meet whatever recommendations have been agreed.

This standard does not cover the following:

  • smoke clearance, where smoke is exhausted from a building after the fire has been suppressed;

  • cross-ventilation, where wind-induced or fan-induced air currents sweep smoke through and out of the building, usually as part of fire-fighting operational procedures;

  • ventilation of stairwells, which usually represents a special application of smoke clearance and which does not necessarily protect the continued use of the stairwell;

  • fully-involved fires.