Homepage>BS 7346-7:2013 Components for smoke and heat control systems Code of practice on functional recommendations and calculation methods for smoke and heat control systems for covered car parks
Sponsored link
sklademVydáno: 2013-08-31
BS 7346-7:2013 Components for smoke and heat control systems Code of practice on functional recommendations and calculation methods for smoke and heat control systems for covered car parks

BS 7346-7:2013

Components for smoke and heat control systems Code of practice on functional recommendations and calculation methods for smoke and heat control systems for covered car parks

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
357.88 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
35.79 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
107.36 €
Anglicky Hardcopy
In stock
357.88 €
Označení normy:BS 7346-7:2013
Počet stran:48
Vydáno:2013-08-31
ISBN:978 0 580 79205 2
Status:Standard
DESCRIPTION

BS 7346-7:2013


This standard BS 7346-7:2013 Components for smoke and heat control systems is classified in these ICS categories:
  • 13.220.20 Fire protection

This part of BS 7346 gives guidance on functional recommendations and calculation methods for smoke and heat control systems for covered parking areas for cars and light commercial vehicles.

NOTE 1 It is assumed that cars powered by fuels other than petrol or diesel will have a fire performance similar to vehicles powered by petrol or diesel. This assumption might be revised in a future edition of this standard if further information suggests it is necessary.

It is intended for system designers, installers of systems, regulatory authorities, for example building control officers and fire safety officers, and those who manage the fire safety of car parks.

It gives recommendations for systems designed for open-sided car parks and for enclosed car parks. It covers:

  • systems intended to protect means of escape for occupants of the car park or the building housing the car park;

  • systems intended to assist active fire-fighting operations; and

  • systems intended to provide smoke clearance following suppression of a fire.

It includes recommendations for natural open-sided ventilation and for ducted mechanical ventilation. It includes guidance on performance-based smoke control using impulse ventilation systems and smoke and heat exhaust ventilation systems (SHEVS). Time-dependent and steady-state design methods are included as appropriate for each smoke control approach. Control of vehicle pollutant emissions is included where it influences the optimization of smoke control. Following the BRE fire tests on car stacker systems, it also includes recommendations for fire sizes and fire suppression in these types of installations.

Smoke and heat control systems for loading bays and coach parks are not covered by this standard.