BS 8519:2020 Selection and installation of fire-resistant power and control cable systems for life safety, fire-fighting and other critical applications. Code of practice

BS 8519:2020

Selection and installation of fire-resistant power and control cable systems for life safety, fire-fighting and other critical applications. Code of practice

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
328.12 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
32.81 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
98.44 €
Anglicky Hardcopy
In stock
328.12 €
Označení normy:BS 8519:2020
Počet stran:48
Vydáno:2020-06-25
ISBN:978 0 539 00951 4
Status:Standard
DESCRIPTION

BS 8519:2020


This standard BS 8519:2020 Selection and installation of fire-resistant power and control cable systems for life safety, fire-fighting and other critical applications. Code of practice is classified in these ICS categories:
  • 29.060.01 Electrical wires and cables in general
  • 13.220.20 Fire protection

This British Standard gives recommendations and guidance on the selection and installation of fire-resistant power and control cable systems which need to maintain their circuit integrity for life safety and fire-fighting. It also gives specific recommendations for electrical system design for such applications, and for fire survival times.

This British Standard is primarily intended for use in buildings which, due to their size, height, form or use, require the installation of life safety and fire-fighting systems, e.g. sprinkler pumps, wet riser pumps, smoke control systems, fire-fighting and evacuation lifts or other systems as required by the fire engineered strategy.

It covers:

  • the source of supply;

  • the distribution voltage [high voltage (HV) or low voltage (LV)]; and

  • the appropriate location of the main intake rooms, HV switchrooms, LV switchrooms, transformer rooms, generator rooms, risers, fire life safety equipment plant rooms and fire‑fighting/evacuation lift motor rooms/shafts.

The British Standard can also be used for systems which need to maintain their circuit integrity during a fire because the function they support is critical for business continuity, property protection or environmental protection reasons.

This British Standard does not give recommendations for those installations covered in BS 5839‑1, BS 5839‑8, BS 5839‑9 and BS 5266‑1, but makes reference to these standards.