Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS EN 12101-13:2022 Smoke and heat control systems Pressure differential systems (PDS). Design and calculation methods, installation, acceptance testing, routine testing and maintenance
Sponsored link
sklademVydáno: 2022-10-27
BS EN 12101-13:2022 Smoke and heat control systems Pressure differential systems (PDS). Design and calculation methods, installation, acceptance testing, routine testing and maintenance

BS EN 12101-13:2022

Smoke and heat control systems Pressure differential systems (PDS). Design and calculation methods, installation, acceptance testing, routine testing and maintenance

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
407.25 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
40.73 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
122.18 €
Anglicky Hardcopy
In stock
407.25 €
Označení normy:BS EN 12101-13:2022
Počet stran:126
Vydáno:2022-10-27
ISBN:978 0 539 24261 4
Status:Standard
DESCRIPTION

BS EN 12101-13:2022


This standard BS EN 12101-13:2022 Smoke and heat control systems is classified in these ICS categories:
  • 13.220.99 Other standards related to protection against fire
This document gives calculation methods, guidance and requirements for the design, installation, acceptance testing, routine testing and maintenance for pressure differential systems (PDS). PDSs are designed to hold back smoke at a leaky physical barrier in a building, such as a door (either open or closed) or other similarly restricted openings and to keep tenable conditions in escape and access routes depending on the application. It covers systems intended to protect means of escape e.g. staircases, corridors, lobbies, as well as systems intended to provide a protected firefighting space (bridgehead) for the fire services. It provides details on the critical features and relevant procedures for the installation. It describes the commissioning procedures and acceptance testing criteria required to confirm that the calculated design is achieved in the building. This document gives rules, requirements and procedures to design PDS for buildings up to 60 m. For buildings taller than 60 m the same requirements are given (e.g. Table 1), but additional methods of calculation and verification are necessary. Requirements for such methods and verification are given in Annex D, but the methods fall outside the scope of this document [e.g. Additional mathematical analysis and/or Computational Fluid Dynamics (CFD)]. Routine testing and maintenance requirements are also defined in this document. In the absence of national requirements and under expected ambient and outside conditions, the requirements in Table 1 are fulfilled by the PDS.