Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS EN 13565-2:2018 Fixed firefighting systems. Foam systems Design, construction and maintenance
Sponsored link
sklademVydáno: 2021-06-23
BS EN 13565-2:2018 Fixed firefighting systems. Foam systems Design, construction and maintenance

BS EN 13565-2:2018

Fixed firefighting systems. Foam systems Design, construction and maintenance

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
357.24 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
35.72 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
107.17 €
Anglicky Hardcopy
In stock
357.24 €
Označení normy:BS EN 13565-2:2018
Počet stran:50
Vydáno:2021-06-23
ISBN:978 0 539 17408 3
Status:Standard
DESCRIPTION

BS EN 13565-2:2018


This standard BS EN 13565-2:2018 Fixed firefighting systems. Foam systems is classified in these ICS categories:
  • 13.220.20 Fire protection

This document specifies the requirements and describes the methods for design, installation, testing and maintenance of low, medium, and high expansion foam fire extinguishing systems.

Foam systems may be used to suppress the release of toxic vapours but this application is outside the scope of this document.

This document provides guidance for the design of various foam systems available to persons with knowledge and experience in determining the selection of foam fire extinguishing systems which will be effective in protecting specific hazard configurations. For the application of this standard, a risk assessment by a qualified and experienced person should be performed for both new and existing systems, however the risk assessment is outside the scope of this document.

This document does not cover a risk analysis carried out by a competent person.

Nothing in this document is intended to restrict new technologies or alternative arrangements, provided that the level of foam system performance prescribed in this standard is not lowered, and supported by documented evidence/test reports.

All foam systems are generally unsuitable for the following:

  • chemicals, such as cellulose nitrate, that release sufficient oxygen or other oxidizing agents which can sustain combustion;

  • energized unenclosed electrical equipment;

  • metals such as sodium, potassium and sodium-potassium alloys which are reactive to water;

  • hazardous, water–reactive materials such as triethyl-aluminium and phosphorous pentoxide;

  • combustible metals such as aluminium and magnesium.