Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS EN 14705:2005 Heat exchangers. Method of measurement and evaluation of thermal performances of wet cooling towers
Sponsored link
sklademVydáno: 2005-07-28
BS EN 14705:2005 Heat exchangers. Method of measurement and evaluation of thermal performances of wet cooling towers

BS EN 14705:2005

Heat exchangers. Method of measurement and evaluation of thermal performances of wet cooling towers

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
377.63 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
37.76 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
113.29 €
Anglicky Hardcopy
In stock
377.63 €
Označení normy:BS EN 14705:2005
Počet stran:66
Vydáno:2005-07-28
ISBN:0 580 46406 7
Status:Standard
DESCRIPTION

BS EN 14705:2005


This standard BS EN 14705:2005 Heat exchangers. Method of measurement and evaluation of thermal performances of wet cooling towers is classified in these ICS categories:
  • 27.060.30 Boilers and heat exchangers
  • 27.200 Refrigerating technology
This European Standard specifies requirements, test methods and acceptance tests for thermal performances pumping head verification of wet cooling towers and plume abatement for wet/dry cooling towers. This European Standard is applicable to natural draught wet cooling towers (see in 3.1.2.2) fan assisted natural draught cooling tower (see 3.1.2.3), wet/dry cooling towers (see 3.1.2.4) and "Mechanical draught cooling towers", except series ones. It specifies the test methods, the apparatus required, the limitation of errors and the method for results examination. The acceptance testing covers the verification of the thermal performance data and pumping head of the cooling tower as specified in the contract between the supplier and the purchaser. If these tests are required then this should be recognized at the time of the contract, as additional fittings, and preparations for the test may be required. Deviations from the rules laid down below as well as additions need special agreement between purchaser and supplier and should be documented. This standard does not apply to mechanical draught series wet cooling towers which are dealt with in prEN 13741. NOTE Terms like "design", "values", "guarantee" and "acceptance" used in this standard should be understood in a technical but not in a legal or commercial sense.