Homepage>BS EN 15182-3:2019 Portable equipment for projecting extinguishing agents supplied by firefighting pumps. Hand-held branchpipes for fire service use Smooth bore jet and/or one fixed spray jet angle branchpipes PN 16
Sponsored link
sklademVydáno: 2019-09-24
BS EN 15182-3:2019 Portable equipment for projecting extinguishing agents supplied by firefighting pumps. Hand-held branchpipes for fire service use Smooth bore jet and/or one fixed spray jet angle branchpipes PN 16

BS EN 15182-3:2019

Portable equipment for projecting extinguishing agents supplied by firefighting pumps. Hand-held branchpipes for fire service use Smooth bore jet and/or one fixed spray jet angle branchpipes PN 16

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
165.37 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
16.54 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
49.61 €
Anglicky Hardcopy
In stock
165.37 €
Označení normy:BS EN 15182-3:2019
Počet stran:12
Vydáno:2019-09-24
ISBN:978 0 580 99379 4
Status:Standard
DESCRIPTION

BS EN 15182-3:2019


This standard BS EN 15182-3:2019 Portable equipment for projecting extinguishing agents supplied by firefighting pumps. Hand-held branchpipes for fire service use is classified in these ICS categories:
  • 13.220.10 Fire-fighting

In addition to the requirements given in ENÃ? 15182ââ?¬â??1:2019, this document applies to hand-held branchpipes with smooth bore jet and/or one fixed spray jet angle branchpipes with a nominal pressure of 16 bar (1,6Ã? MPa) PNÃ? 16, with a maximum flow rate up to 1Ã? 000Ã? l/min at a reference pressure of 6 bar (0,6Ã? MPa). It deals with:

  • safety requirements;

  • performance requirements;

  • test methods.

This document applies to branchpipes as defined in AnnexÃ? A of ENÃ? 15182ââ?¬â??1:2019.

WARNING� 1

These branchpipes offer no or inadequate protection for firefighters when the spray angle is less than 30� �° and therefore, are not be used in high risk firefighting situations such as internal attack.

WARNING� 2

These branchpipes should not be used when fighting fires in or near electrical installations when the spray angle is less than 30�° without written authorization from the manufacturer in the manual. This authorization from the manufacturer includes safety distances.