Homepage>BS EN 16329:2022 - TC Tracked Changes. Diesel and domestic heating fuels. Determination of cold filter plugging point. Linear cooling bath method
Sponsored link
sklademVydáno: 2023-02-10
BS EN 16329:2022 - TC Tracked Changes. Diesel and domestic heating fuels. Determination of cold filter plugging point. Linear cooling bath method

BS EN 16329:2022 - TC

Tracked Changes. Diesel and domestic heating fuels. Determination of cold filter plugging point. Linear cooling bath method

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
273.96 €
Anglicky Hardcopy
In stock
273.96 €
Označení normy:BS EN 16329:2022 - TC
Počet stran:52
Vydáno:2023-02-10
ISBN:978 0 539 25805 9
Status:Tracked Changes
DESCRIPTION

BS EN 16329:2022 - TC


This standard BS EN 16329:2022 - TC Tracked Changes. Diesel and domestic heating fuels. Determination of cold filter plugging point. Linear cooling bath method is classified in these ICS categories:
  • 75.160.20 Liquid fuels
This document specifies an automated method for the determination of the cold filter plugging point (CFPP) of diesel and domestic heating fuels using linear cooling. This document is applicable to fatty-acid methyl esters (FAME) and to distillate fuels as well as paraffinic diesel fuels, including those containing FAME, flow-improvers or other additives, intended for use in diesel engines and domestic heating installations. The results obtained from the method specified in this document are suitable for estimating the lowest temperature at which a fuel will give trouble-free flow in the fuel system. NOTE In the case of diesel fuels, the results are usually close to the temperature of failure in service except when the fuel system contains, for example, a paper filter installed in a location exposed to the weather or if the filter plugging temperature is more than 12 °C below the cloud point of the fuel. Domestic heating installations are usually less critical and often operate at a satisfactory level at temperatures somewhat lower than those indicated by the test results. WARNING - The use of this document can involve hazardous materials, operations and equipment. This document does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this document to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.