Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS EN 16612:2019 Glass in building. Determination of the lateral load resistance of glass panes by calculation
Sponsored link
sklademVydáno: 2019-11-04
BS EN 16612:2019 Glass in building. Determination of the lateral load resistance of glass panes by calculation

BS EN 16612:2019

Glass in building. Determination of the lateral load resistance of glass panes by calculation

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
376.35 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
37.64 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
112.91 €
Anglicky Hardcopy
In stock
376.35 €
Označení normy:BS EN 16612:2019
Počet stran:56
Vydáno:2019-11-04
ISBN:978 0 580 97580 6
Status:Standard
DESCRIPTION

BS EN 16612:2019


This standard BS EN 16612:2019 Glass in building. Determination of the lateral load resistance of glass panes by calculation is classified in these ICS categories:
  • 81.040.20 Glass in building

This document gives a method of determining the design value of the bending strength of glass. It gives the general method of calculation, and guidance for lateral load resistance of linearly supported glazed elements used as infill panels.

NOTE

Examples of lateral loads are wind loads, snow loads, self weight of sloping glass, and cavity pressure variations on insulating glass units.

This document gives recommended values for the following factors for glass as a material:

— material partial factors, ? M;A and ? M;v ;

— factors for the load duration, kmod ;

— factor for stressed edges, ke.

Most glass in buildings is used as infill panels. This document covers those infill panels that are in a class of consequence lower than those covered in EN 1990, so proposed values for the partial load factors, ?Q and ?G, are given for these infill panels.

The action of cavity pressure variations on insulating glass units is not covered by Eurocodes, so this document also gives proposed values of combination factors, ?0, ?1 and ?2, for this action.

This document does not determine suitability for purpose. Resistance to lateral loads is only one part of the design process, which could also need to take into account:

  • in-plane loading, buckling, lateral torsional buckling, and shear forces,

  • environmental factors (e.g. sound insulation, thermal properties),

  • safety characteristics (e.g. fire performance, mode of breakage in relation to human safety, security).

This document does not apply to channel shaped glass, glass blocks and pavers, or vacuum insulated glass units.