Homepage>BS EN 16798-7:2017 Energy performance of buildings. Ventilation for buildings Calculation methods for the determination of air flow rates in buildings including infiltration (Modules M5-5)
sklademVydáno: 2017-07-14
BS EN 16798-7:2017 Energy performance of buildings. Ventilation for buildings Calculation methods for the determination of air flow rates in buildings including infiltration (Modules M5-5)

BS EN 16798-7:2017

Energy performance of buildings. Ventilation for buildings Calculation methods for the determination of air flow rates in buildings including infiltration (Modules M5-5)

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
345.31 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
34.53 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
103.59 €
Anglicky Hardcopy
In stock
345.31 €
Označení normy:BS EN 16798-7:2017
Počet stran:62
Vydáno:2017-07-14
ISBN:978 0 580 85877 2
Status:Standard
DESCRIPTION

BS EN 16798-7:2017


This standard BS EN 16798-7:2017 Energy performance of buildings. Ventilation for buildings is classified in these ICS categories:
  • 91.120.10 Thermal insulation of buildings
  • 91.140.30 Ventilation and air-conditioning systems
This European Standard describes the methods to calculate the ventilation air flow rates for buildings to be used for energy calculations evaluation, heating and cooling loads. This European Standard applies to buildings with: - Mechanical ventilation systems (mechanical exhaust, mechanical supply or balanced system); - Passive duct ventilation systems for residential and low-rise non-residential buildings; - Combustion appliances; - Windows opening by manual operation; - Kitchens where cooking is for immediate use (including restaurants) This European Standard is applicable to hybrid systems combining mechanical and passive duct ventilation systems in residential and low-rise non-residential buildings. This European Standard applies to buildings smaller than 100 m and rooms where vertical air temperature difference is smaller than 15 K. The results provided by the standard are: ? the air flow rates entering or leaving a ventilation zone; - the air flow rates required to be distributed by the mechanical ventilation system, if present. This European Standard is not applicable to: - Buildings with kitchens where cooking is not for immediate use - Buildings with automatic windows (or openings) - Buildings with industry process ventilation. The definition of ventilation and airtightness requirements (as indoor air quality, heating and cooling, safety, fire protection…) is not covered by this standard. The following information can be found in other standards and technical reports: - guidance to estimate pressure drops in ducts (CR 14378:2002) Table 1 shows the relative position of this standard within the EN EPB package of standards.