Vážení zákazníci, v letošním roce budeme expedovat poslední objednávky ve středu 18. 12. 2024.

Těšíme se s vámi na shledanou od pondělí 06. 01. 2025.

 

Menu
0
Total price
0 €
PRICES include / exclude VAT
Homepage>BS EN 50443:2011 Effects of electromagnetic interference on pipelines caused by high voltage a.c. electric traction systems and/or high voltage a.c. power supply systems
Sponsored link
sklademVydáno: 2012-01-31
BS EN 50443:2011 Effects of electromagnetic interference on pipelines caused by high voltage a.c. electric traction systems and/or high voltage a.c. power supply systems

BS EN 50443:2011

Effects of electromagnetic interference on pipelines caused by high voltage a.c. electric traction systems and/or high voltage a.c. power supply systems

Format
Availability
Price and currency
Anglicky Secure PDF
Immediate download
271.50 €
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
27.15 €
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
81.45 €
Anglicky Hardcopy
In stock
271.50 €
Označení normy:BS EN 50443:2011
Počet stran:32
Vydáno:2012-01-31
ISBN:978 0 580 54804 8
Status:Standard
DESCRIPTION

BS EN 50443:2011


This standard BS EN 50443:2011 Effects of electromagnetic interference on pipelines caused by high voltage a.c. electric traction systems and/or high voltage a.c. power supply systems is classified in these ICS categories:
  • 33.100.01 Electromagnetic compatibility in general
  • 29.280 Electric traction equipment
  • 23.040.99 Other pipeline components

The presence of a.c. power supply systems or of a.c. electric traction systems (in this standard also indicated as a.c. power systems) may cause voltages to build up in pipeline systems, (in this standard indicated as interfered systems) running in the close vicinity, due to one or more of the following mechanisms:

  • inductive coupling,

  • conductive coupling,

  • capacitive coupling.

Such voltages may cause danger to persons, damage to pipelines or connected equipment or disturbance to the electrical/ electronic equipment connected to the pipeline.

This European Standard deals with the situations where these effects may arise and with the maximum tolerable limits of the interference effects, taking into account the behaviour of the a.c power systems both in normal operating condition and/or during faults.

NOTE In the worst case, the pipe may not disperse current to ground. As a consequence, the prospective touch voltage coincides with the interference voltage.

This European Standard applies to all metallic pipelines irrespective of the conveyed fluid, e.g. liquid or gas, liable to be interfered by high voltage a.c. railway and high voltage a.c. power supply systems.

The objective of this standard is to establish:

  • the procedure for evaluating the electromagnetic interference;

  • the interference distance to be considered;

  • the types of coupling to be considered for operating and fault conditions of the high voltage a.c. electric traction systems and high voltage a.c. power supply systems;

  • the configurations to be considered for both metallic pipeline and high voltage a.c. electric traction systems or high voltage a.c. power systems;

  • the limits of the voltages due to the electromagnetic interference;

  • information on interference situations, calculation methods, measuring methods, mitigation measures, management of interference.

This European Standard is applicable to all new metallic pipelines and all new high voltage a.c. electric traction systems and high voltage a.c. power supply systems and all major modifications that may change significantly the interference effect.

This European Standard only relates to phenomena at the fundamental power frequency (e.g. 50 Hz or 16,7 Hz).

This European Standard does not apply to:

  • all aspects of corrosion,

  • the coupling from a.c. railway and power supply systems with nominal voltages less than or equal to 1 kV,

  • interference effects on the equipment not electrically connected to the pipeline.